Combustion air supply
The burner must be supplied with suf icient fresh combustion air. If necessary, create an additional air
supply opening, as close to the burner as possible, to avoid drafts. The air supply in the room should
have a minimum size of 150 cm2. An additional air supply opening is absolutely required if:
•
The room is equipped with a heat recovery system.
•
The room is equipped with a central extraction system.
•
An extractor hood is located in the same room.
The air supply opening must not be closed in these cases. The air supply opening must be sealable if it
passes through a irewall. If several combustion appliances are present in the same room, there must
be suf icient air supply openings to ensure trouble-free combustion.
An external air supply may be ordered as an option for this burner (see page
35
). Order number OND.
SM.1005.
Decorative trim and mounting frame
Please refer to the instructions provided with the various trim strips. Please note that in some cases,
especially for the corner models, it is easier to mount the trim on the burner before installation.
Connecting the burner
The WAN-2060 is a medium-heavy (80 kg) wood-burner. Make sure that the loor on which you place
the ire is strong enough and lat. Before assembling the burner, follow the instructions in the previous
section ‘Preparation’. Protect your back and the loor during the entire assembly.
1.
Check the packaging, and if there are any visible damages, report them
2.
Take the burner out of the box
3.
Remove the baf le plate from the burner
4.
Remove the pipe opening from the burner by unscrewing the 4 screws
5.
Insert the burner in its recess, making sure that it is exactly in the middle under the
chimney opening.
6.
Connect the pipe opening to the chimney duct
7.
Place the baf le plate in the burner
8.
Install the trim (note that in some cases it is better to install the trim beforehand)
9.
Your ireplace is ready for use
Summary of Contents for WAN-2060F
Page 16: ...KEERPLAAT PIJPMOND...
Page 18: ...Technische tekening...
Page 19: ...Externe lucht aansluiting...
Page 33: ...BAFFLE PLATE PIPE...
Page 35: ...Technical drawings...
Page 36: ...External air supply connection...
Page 50: ...D FLECTUER MANCHON...
Page 52: ...Dessins techniques...
Page 53: ...Raccordement de l air ext rieur...
Page 67: ...Herausnehmbarer Ofenstuzen...
Page 68: ...Umlenkplatte Herausnehmbarer Ofenstuzen...
Page 70: ...Technische Daten...
Page 71: ...Technische Zeichnungen...