19
GB
General
instructions
19
Preparation
19
Fire
Safety
19
Installation
20
Repairs
20
Technical
details
Solea
21
General instructions
The Solea is tested in accordance with the international
EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to flue gases (Section 15a B-Vg.
Des BmfWA). The stove can be connected to a flue
tube to which several stoves are connected. The Solea
should never been integrated into the construction of the
room.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee
if the stove is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
t "SDBEFTBOEDPSSJEPSTBDDFTTJCMFUPUIFQVCMJD
t 4UBJSXFMMT FYDFQU JO CVJMEJOHT XJUI OP NPSF UIBO
dwellings.
t 4QBDFTXIFSFIJHIMZnBNNBCMFPSFYQMPTJWFNBUFSJBMT
are used.
t 4QBDFTXIFSFBOFYIBVTUTZTUFNJTVTFEPSXIFSFB
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney flue
Before placing the stove you must observe the following
points:
t *GUIFTUPWFJTDPOOFDUFEUPBOFYJTUJOHDIJNOFZZPV
must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company.
Any cut-off valves or stop valves must be removed.
t 5IFnVFUVCFPGUIFTUPWFNVTUCFDPOOFDUFEXJUIUIF
chimney without diversions.
t 5IFVOEFSQSFTTVSFJOUIFDIJNOFZNVTUCFBUMFBTU
Pa or 0.12 mbar.
t 5IFDIJNOFZnVFNVTUBMXBZTFOEVQJOPVUMFUBSFB
(see the drawing below)
t "U UIF UJNF PG QMBDJOH UIF TUPWF UIF DIJNOFZ nVF
must be clean, leak-proof and without obstructions,
and must have a diameter of 150 mm.
t "OZ CFOET JO UIF nVF UVCF NVTU OPU FYDFFE
degrees.
t &OTVSFUIBUUIFDIJNOFZUVCFDBOEJTDIBSHFUIFnVF
gases adequately, properly and safely.
t 5IFWBMVFTGPSDBMDVMBUJOHUIFDIJNOFZUVCFJTHJWFO
in the section on Technical Information, see above.
Fire Safety
For reasons of fire safety is it important to observe the
instructions below before installing the stove.
1. The free distance from the fire-proof rear wall is at
least 10 cm in each rotated position.
2. Keep at least a distance of 80 cm between the stove
and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects.
Keep the same distance from the flue tube.
3. Wooden construction parts within the radiation
range of the stove (80 cm from the exterior of the
stove) must be covered with fireproof material.
Installation Instructions
Roof slope x larger than 23°
Roof slope x smaller than 23°
Summary of Contents for SOLEA ELEGANCE
Page 12: ...12 User s Guide and Installation Manual Solea GB ...
Page 23: ...23 FR Mode d emploi et instructions d installation Solea FR ...
Page 36: ...36 Gebrauchsanweisung und Installationsvor schriften Solea DE ...
Page 50: ...50 Notitities Notes Notes Notizen ...
Page 51: ...Technische tekeningen Technical drawings Dessins techniques Technische Zeichnungen 51 ...
Page 52: ......