Fire Safety
For reasons of fi re safety is it important to observe the instructions below before installing the stove.
1. If the fl oor around the stove is made of combustible material, you must use a fl oor slab. The fl oor slab must
measure at least:
- 50 cm from the stove on the front side of the door
- 30 cm from the stove on the sides of the door.
2. Keep at least a distance of 100 cm between the stove and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects. Keep the same distance from the fl ue tube.
3. Wooden construction parts within the radiation range of the stove (80 cm from the exterior of the stove) must
be covered with fi reproof material.
4. If the fl ue tube goes through a ceiling and/or roof that consist of fl ammable materials, the ceiling and the roof
must be covered with fi reproof materials all around (about 80 cm). Pay also attention to joisted fl oor layers and
any electric wiring.
5. Keep a distance of at least 50 cm (in all directions) between the stove and supporting steel construction parts.
6. Shield off all combustible materials within a radius of 100 cm from the stove openings with non-combustible
materials.
7. Never cover the chimney breast with combustible material (e.g. paper covering).
8. The wall behind the stove must consist of, or be insulated with, fi re-proof materials. The insulation material
must resist a temperature of 700 °C and have a density of 80 kg/m3. Please see for insulation materials table
page 27).
Installation
The Elm is tested in accordance with the international EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly heating devices related to fl ue gases. The stove can be
connected to a fl ue tube to which several stoves are connected. The fl ue tube has a diameter of 150 mm.
Supply of combustion air
The stove must have enough supply of fresh combustion air. If necessary, make an extra air supply opening as
close to the stove as possible to avoid draught. An extra opening for air supply is always required if:
•
the space has a heat recovery system.
•
the space has a central exhaust system.
•
there is a cooker hood in the same space.
The air supply opening must be closable if it goes through a fi re-resistant wall. When there are several combustion
devices in the same space there must be enough air openings to guarantee proper combustion.
External air connection
The fresh air supply channel has a diameter of 80 millimetres. The air supply channel can be fi tted via a bottom or
rear connection. If the external air supply goes through a fi rewall, that channel must be able to be shut off . If the