42
4.
Technical data
4.1
Data
4.2
Dimensions
W2-50
screw feet
can raise stove height by +20 mm
The dimension information shown is only for information! We reserve the right to
make changes to the construction if these improve the technical level or the
quality!
Innovation from Tradition
We reserve the right to make changes which relate to technical advances and / or to an improvement
in quality. We accept no liability for printing errors and changes which occur after printing.
Model number
W2 - 50
Nominal heat load
6 kW
Space heating ability in m³ in favourable / less
favourable / unfavourable
conditions according to DIN 18893/TABLE. 2
Short-term heating
Long-term heating
114 / 68 / 46
165 / 95 / 65
Exhaust gas for fuel:
Exhaust gas mass
Exhaust gas connector temperature
Flow pressure at nominal heat load
Particles / dust (based on 13% O2)
CO ( based on 13% O2)
Efficiency
Firewood / Lignite
9,7 / 9,7 g/s
275˚C
12 Pa
≤
40 mg/m³
≤
0,09 %
≥
77 %
X
A
B
30
850 (+20)
695 (+20)
80
900 (+20)
745 (+20)