Floor in front of and under the fireplace
Floors made from combustible materials, such as carpets, parquet floors or cork is to
be protected by a shield of non-combustible material – for example ceramics, stone,
glass or steel – placed under the fireplace so that it should reach out to 50 cm in front
and 30 cm besides.
2.4 Connection of the fireplace
WARNING:
Before connecting the fireplace to the chimney, seek advice from the competent
chimney sweeper!
The connecting elements should be attached to the equipment and to each other in a
properly sealed and stable manner. They may not hang into the unobstructed cross-
section of the chimney. The interconnecting piece between the chimney and the fire-
place should be of the same cross-section size as the pipe stub of the fireplace. Hori-
zontal connecting pieces should ascend to the chimney in 10°. Pipes that are not
heat-protected or not led vertically may not be longer than 1 m.
There should be a minimum distance of 40 cm kept between the connection pieces of
the fireplace and combustible materials in the building. Provided that the interconnect-
ing pieces have a non-combustible coating of minimum 2 cm, the distance from com-
bustible materials may be at least 10 cm. If the interconnecting pieces are led through
equipment or furnishing made from combustible materials, they have to be covered
with a protecting tube made from any non-combustible material in a distance of at
least 20 cm, or they have to be coated with any non-combustible material with low
heat conductance in a minimum range of 20 cm.
Smaller distances to combustible materials are permissible if it is ensured that at the
rated performance of the fireplace the temperature cannot rise over 85°C at the com-
bustible equipment and furnishings.
WARNING:
The connection of the fireplace to the chimney is not permissible if the effective height
of the chimney is less than 4 m, or 5 m with multiple loading (see the details of chim-
ney calculations on 3.).
To the chimney that the fireplace uses, a maximum of two other fireplaces, ovens may
be connected.
The fireplace can usually be
connected to the chimney with
an angle pipe
With weak chimney draught, the
fireplace is to be connected to
the chimney through a vertical
flue gas pipe facilitating dis-
charge.
Summary of Contents for N-LINE 111 55
Page 10: ...10 Ausmauerung Umlenkplatten Bild 2 Bild 3 Bild 4 Bild 5 Bild 6 Bild 7 ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 29: ...29 pic 2 pic 3 pic 4 pic 5 pic 6 pic 7 Furnace cham ber walling Fireclay ...
Page 46: ...46 fig 2 fig 3 fig 4 fig 5 fig 6 fig 7 chamotte Garniture intérieure Vermiculite ...
Page 64: ...64 fig 2 fig 3 fig 4 fig 5 fig 6 fig 7 Muratura Chamotte ...
Page 84: ...84 2 kép 3 kép 4 kép 5 kép 6 kép 7 kép Falazat Lángterelő ...
Page 90: ...90 3 Müszaki adatok 3 1 Méretrajzok Typ 111 55 N Line Súly 122kg ...