6.0 INFORMATION REGARDING USE
2
EXT.SBB-HFF.--.M.A.0219.EN Issue: A
02.19
44
SBB-HFF
Operation of the motovibra-tor will be cyclic or continuous according to the flow required. At the end of the
emptying process, it is advisable to continue to operate the motovibrator for another one or two minutes in
order to remove any product remaining in the folds of the FIBC. Do not start up the motovibrator without the
FIBC or without product.
To unload the FIBC empty the hopper completely, then proceed with the operations indicated in re
-
verse order.
START-UP - ADJUSTING THE ELECTRIC VIBRATOR
If, during operation, there is a problem with downflow of the product, the motovibrator can be adjusted, by
increasing or decreasing its intensity of vibration.
Procedures for adjusting motovibrator
The motovibrator installed is of the variable weights type; it is therefore necessary to change the degree of
intensity of vibrations according to the method described in the (enclosed) USE AND MAINTENANCE manual
supplied by the Manufacturer.
The value of regulation of the motovibrator fitted on the FIBC, is closely linked to the conditions of use.
The adjustment must be made before start-up.
The parameters to be taken into consideration are:
- Type of product;
- Humidity;
- Temperature;
- FIBC storage time;
- Flow rate;
- FIBC dimensions.
The adjustment defined and done by the Manufacturer during the acceptance test phase is 50%.
If it is necessary to change this value, it is advisable to proceed gradually and to contact the Manufacturer.
If the results are not satisfactory, before proceeding with another adjustment, empty the product from the hop-
per in order to avoid residue from previous tests.
THE OPERATION MUST BE CARRIED OUT EXCLUSIVELY BY QUALIFIED PERSONNEL, WITH THE
POWER SUPPLY DISCONNECTED.
3000 rpm
SBB
Model
Vibrators
Electric features
Mechanical features
no.
Vibrator Mode
Fre-
quency
Input
Power
Max Current (A)
Speed
(rpm)
FC
50%
(kg)
Weight
(kg)
Nominal Voltage
kW
230 V 400 V 230 V 460 V 220 V/
277 V
380 V/
480 V
125
1
MVE100/3E 10A0
50 Hz
0.09
0.43
0.25
3,000
49.00
5.00
MVE100/36E-10A0
60 Hz
0.09
0.46
0.23
0.40
0.23
3,600
47.50
5.00
125
1
MVE 200/3E 20A0
50 Hz
0.15
0.61
0.35
3,000
93.50
7.00
MVE 200/36E-20A0
60 Hz
0.18
0.60
0.30
0.52
0.30
3,600
94.50
7.00