3  Transport 

3.1  Packaging  

The  type  of  packaging  depends  on  the  individual  mode  of  shipping.  If  not  separately  contracted,  the 
packaging  is  in  accordance  with  the  rules  and  regulations  of Walther  Systemtechnik  GmbH. This  rule  is  in 
accordance with the Federal Association for Packaging HPE. 

 

3.2  Tasks before Transport 

The following has to be done before transport:  

  Disconnect all power lines.  

The actual transport of the incomplete device and its individual parts requires special care in order to prevent 
damages  from  external  forceful  impact  or  careless  on-  and  off-loading.  Depending  on  the  mode  of 
transportation, suitable transport and load securing has to be selected. The incomplete device will be aligned 
and leveled by appropriate fastening elements

.  

4  Description of Function 

The dosing pen 

VMS-13-EH

 is operated by a manual trigger/actuation. The spraying material will be supplied 

from  a  pressure  container  or  via  a  pump  to  the  valve.  The  needle  will  be  pulled  back  and  releases  the 
material  which  is  then  discharged  from  the  nozzle.  The  actual  application  image  can  be  adjusted  via  the 
nozzle or the nozzle extension, as well as the material pressure and the needle stroke settings. 
 

4.1  Designated Purpose 

 

CAUTION 

The use of other media can cause functional failures, damages or even the destruction 
of the device. 

  
 
The 

VMS-13-EH

 dosing pen is a high-precision device which will be a long-term reliable tool if the following 

notes are observed 
 
The function of the needle is as follows: 
Open by using the external controls and close after turn-off of external controls through the spring pressure. 

Summary of Contents for Dosing Pen VMS-13-EH

Page 1: ...EH 1 5 Fig WALTHER Dosing Pen VMS 13 EH NOTE Please read the Assembly Instructions carefully before first using the incomplete device and strictly adhere to the instructions The incomplete device may...

Page 2: ...TA 8 4 4 TYPE LABEL 8 5 INITIAL START UP 9 5 1 MOUNTING AND INSTALLATION 9 5 2 WIRING DIAGRAM MANUAL ACTUATION ART NO 979297 9 6 OPERATION 10 6 1 GENERAL INFORMATION 10 6 2 OPERATION INSTRUCTIONS OPER...

Page 3: ...osing Pen VMS 13 EH Page 3 of 20 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 4 ARTICLE NUMBER FOR...

Page 4: ...sheim Description WALTHER Dosing Pen Article No VMS 13 EH 0 3 VMS 13 EH 0 5 VMS 13 EH 1 0 VMS 13 EH 1 5 We also declare the conformity with other product relevant directives guidelines Mach Direct 200...

Page 5: ...describe possible property damages IMPORTANT Indicates tips for usage and other particularly useful information No dangerous situation 2 Safety 2 1 General Information The construction of the device i...

Page 6: ...or alterations on the device that may hamper its safety without the prior consent of Walther Systemtechnik GmbH Operating the device with defective safety installations or not properly attached or mal...

Page 7: ...of transportation suitable transport and load securing has to be selected The incomplete device will be aligned and leveled by appropriate fastening elements 4 Description of Function The dosing pen V...

Page 8: ...x 20 bar Connection Manual Trigger Control air mm 4 Material mm 6 Spray Head mm G1 8 Manual Actuation Pin 1 and 4 In the basic version the WALTHER Dosing Pen comes without adapter nozzle The adapter n...

Page 9: ...ling a maintenance unit to the control air Connect the WALTHER Dosing Pen VMS 13 EH to a pressure container or a pump via the material connection M6 IG connect to the control air supply min 6 bar via...

Page 10: ...a control air pressure of 3 6 bar Control air pressure and material pressure should be closely correlated IMPORTANT Accident prevention directions will be strictly followed when applying high materia...

Page 11: ...Please follow the maintenance guidelines 8 Maintenance and Repair 8 1 General Information The dosing pens of the VMS 13 EH series are high quality precision devices which will not fail if treated cor...

Page 12: ...g new Gasket Elements IMPORTANT Gaskets and gasket holders can be damaged Do not use any sharp or pointed metallic implements for inserting the sealings 8 4 Replacing Nozzle 1 TEFLON sealing 5 and Nee...

Page 13: ...9 1 General Information IMPORTANT First check all supply lines for connection and serviceability In case of serious problems that cannot be resolved please contact the Walther Systemtechnik GmbH cust...

Page 14: ...sheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 Appendix 10 1 Spare Part Drawing VMS 13 EH 10 1 1 Spare Part List for VMS 13 EH Dwg No Art No...

Page 15: ...tructions Dosing Pen VMS 13 EH Page 15 of 20 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 2 Spare...

Page 16: ...640004 1 Variseal 2 65 x 2 0 x 2 8 6 97640021 1 O Ring 6 07 x 1 78 Viton 7 97810013 1 Sealing screw diam 11 x 21mm 8 97640026 1 O Ring 2 90 x 1 78 Viton 9 1 97112293 1 Nozzle needle KV 0 2 1 5mm 2 x 9...

Page 17: ...sing Pen VMS 13 EH Page 17 of 20 Walther Systemtechnik GmbH D 76726 Germersheim Telefon 49 0 7274 7022 0 Telefax 49 0 7274 7022 91 http www walther 2000 de info walther 2000 de 10 3 Spare Part Drawing...

Page 18: ...joint G1 4 6 10 97432241621 1 Straight connection 6 24162 1 11 97432230311 1 Screw down holder for hose connector 12 97166080P 0 2m High pressure hose L800 NW4 13 970720411 1 Connector M6 14 252 22 E...

Page 19: ...53 Adapter made of aluminium for foam 979756 Interchange parts made of foam 979752 Adapter made of aluminium for felt 979735 Interchange parts made of felt with plastic cap size 15x6mm 979735 01 Inter...

Page 20: ...t pen 9713898 Brush made of horsehair 6 5 mm 1 8 9713899 Brush made of horsehair 16 mm 1 8 9712522 Brush made of perlon 6 5 mm to 70 C 1 8 9712519 Brush made of perlon 16 mm to 70 C 1 8 BT SOFT 16 Bru...

Reviews: