Rev. 1.2
Assembly Instructions
– Dosing Pen VMS-13-EH
Page 9 of 20
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
5 Initial Start- up
The valves can be used in any position; the distance to the application area depends on the desired
application width.
5.1 Mounting and Installation
IMPORTANT
We recommend installing a maintenance unit to the control air
.
Connect the WALTHER Dosing Pen
VMS-13-EH
to a pressure container or a pump via the material
connection (M6 IG); connect to the control air supply (min. 6 bar) via the hose connection (15). When using
an adapter nozzle, install the required attachment. Set material pressure at the container or the pump (max.
pressure: 20 bar). The material will now be released when you use the external controls.
5.2 Wiring Diagram
– Manual Actuation Art. No.: 979297
Button connector to Pin1 and Pin4
Material connection „M“
Compressed air connection
„SL control air blue“
Connection
„manual actuation“