Revision 15
16
To cancel the
Lockout
function when it has been activated due to excessive
operations and allow the unit to operate normally again, carry out the following
steps:
1.
Switch off the power to the control unit for 5 seconds.
2.
Switch on the power to the control unit.
3.
Check that the basin/bath, shower and WC are operating correctly.
4.
An option to connect a switch to an auxiliary input that is set for
Reset Lockout
is available, contact Wallgate for additional information.
5.6.3.
Piezo touch button and infrared sensor controls
Piezo touch buttons and infrared sensors can be connected to the control unit to
operate the basin/bath, shower and WC. You can connect either Piezo touch
buttons or infra-red sensors to the control unit.
The control unit is set for use with Piezo touch buttons by default.
If you connect infrared sensors to the control unit, you must modify the applicable
setting. For instructions on how to do this, refer to
Table 5
on page 23.
You do not have to modify this setting if the control unit is factory set for operation
with infrared sensors.
The Piezo touch buttons do not have any moving parts.
To operate the Piezo touch button:
1.
Press the center of the button to start the operation.
2.
Press the center of the button to stop the operation (for basin/bath hot and cold
only).
To operate the infrared sensor:
1.
Hold your hand within 50mm of the infrared sensor.
NOTE: Infrared sensors cannot stop or interrupt an operation until the
operation is complete. Piezo touch buttons can interrupt or stop an operation.
For example, you can interrupt a basin operation by pressing the piezo button
again. You cannot interrupt a basin operation by operating the infrared sensor
again.