5.5.
Connect the Electrical Supply
To make the electrical connections to the control unit:
WARNING! The electrical connections must be made by a qualified electrical
engineer in accordance with the present nationally approved IEE Regulations.
1.
Terminate the supply cable from the control unit into the spur connection outlet
and fit a 2 Amp fuse.
2.
Connect an earth conductor to the water supply pipes on the basin/bath and
shower nozzles. The other end of the earth conductor must be connected to an
approved earth facility.
NOTE: The water pipes connected to the basin/bath taps and shower nozzles
must be bonded to earth.
3.
Make sure that the Piezo touch button or infra-red sensor leads from the
basin/bath tap, shower and WC are plugged into the correct sockets on the base
of the control unit. Refer to section 5.4 or the label on the front of the unit.
4.
Complete electrical testing of the installation.