23
3.
Per national and local regulations only connect
your charger to a circuit with a branch circuit
overcurrent protection of 125% of the selected max
amperage setting of the device.
As per the chart below:
For this limitation take only into account the wire and breaker
installed for the EV charger.
To ensure a safe installation, we recommend working
with a licensed installer or electrician. A professional
electrician can perform the necessary load calculations
to determine the maximum safe installation.
4.
Close the cover of the charger following the
instructions in the
Installation
4
2
6
24A
16A
40A
30A
20A
50A
Position
Amps
Circuit Breaker Rating
5
3
7
32A
20A
48A
40A
25A
60A