Operator’s Manual and Installation Guide

 

 

3

Mounting the device 
 

Attach the furnace mounting bracket to the dampening plate (figure 2). Attach the 
dampening plate to the bulkhead (figure 3). Attach the furnace to the mounting piece by 
clicking the rails of the mounting piece to the grooves in the sides of the furnace (figure 
4). Lock the furnace in place through its suspension loops with the two long mounting 
bolts (figure 5).  The furnace can be fitted to the bracket with the outlets at either end. 

 
Mounting the control panel 

Control panels are attached to the wall with the enclosed screws (figure 6). If desired, it 
is possible to flush mount by removing the collar of the control panel, although this collar 
needs to be used on the Info Panel if the thermostatic feature is to be functional. 
 

NOTE: 

This furnace is made for marine use at or near sea level. 

Not for unattended 

use. 

 

 
Space Requirements 
 

The furnace may be mounted either on a bulkhead or under the deck, and should be 
vertical when the boat is on an even keel.  Although the furnace can withstand some 
tilting and large angles temporarily, the burner will not perform optimally if it is constantly 
at an angle. 
 
The installation must maintain a minimum of 8 inches under the furnace to facilitate 
maintenance, otherwise removal of the unit will be necessary for maintenance. 
 
To avoid galvanic corrosion, the furnace should be isolated from the metal framework of 
the boat.  
 
Take into consideration that the standard length of the control panel harness is 20ft. A 
33ft extension is also available. 

 
Exhaust pipe 

 
The longest permissible exhaust gas pipe is 13ft.  Exhaust runs over 8’ should not have 
more than 360 degrees of turns.  Turns should be as long radius as the installation 
allows. 
 
The exhaust through hull fitting may be installed into the hull, the transom or the deck, 
depending on fitting type, hull design and other factors.  If a deck fitting is desired and 
heavy water on deck is expected, then a closeable deck fitting (2460) with an extension 
(2069) should be used.  On heeling sailboat through hull applications, the through hull 
fitting should be installed as far aft as possible, preferably at the stern.  Recommended 
distance from the through hull fitting to the surface of the water is at least 12 inches.  
 
Exhaust gas is hot! The exhaust pipe and fittings must be insulated well and installed 
away from flammable materials.  Air must be allowed to flow freely past either the 
through hull or deck fitting.   Please contact Scan Marine for information. 

Summary of Contents for Nautic 40D

Page 1: ...WALLAS 40D Operator s Manual and Installation Guide 1 2010 Two Mac Inc...

Page 2: ...el options include a Basic Control Panel with indicator lamps or a Digital Info Control Panel The furnace is made entirely of marine grade materials Table 1 Technical details of furnace 40D TECHNICAL...

Page 3: ...tantly at an angle The installation must maintain a minimum of 8 inches under the furnace to facilitate maintenance otherwise removal of the unit will be necessary for maintenance To avoid galvanic co...

Page 4: ...wo M8 x 120 locking bolts Figure 6 Attaching the control panel Note either the 3004 or 3005 can be mounted with or without the bezel shown here 3005 panel must have the bezel fitted for thermostat to...

Page 5: ...WALLAS 40D Operator s Manual and Installation Guide 5...

Page 6: ...WALLAS 40D Operator s Manual and Installation Guide 6...

Page 7: ...n order to secure sufficient air flow the heating air must be divided into at least three outlet vents The ducting attaches to two 3 inch 75mm outlet adaptors at the end of the furnace The longest per...

Page 8: ...safety reasons the furnace must not be installed In a place where gasoline fumes might be present The suction air is taken in via two branches of ducting One inlet duct should take in some fresh air...

Page 9: ...e the power switch to the OFF position The furnace cannot be restarted until the cooling fans have stopped and all indicator lamps have gone out Once the indicator lamps have gone out restart the furn...

Page 10: ......

Page 11: ...at When installing please note the thermostat manufacturer s instructions The thermostat will not switch the furnace on or off but will adjust the furnace between minimum power and the user determined...

Page 12: ...WALLAS 40D Operator s Manual and Installation Guide 12 Figure 15 Figure 14...

Page 13: ...mportant 1 Make sure the fuel line end is cut cleanly and squarely 2 Slide the nut on the fuel line with the threads toward the line end 3 Push the acorn over the end of the fuel line 4 Slide the ferr...

Page 14: ...ngine pickup Install a filter in the fuel line Note the need for replacing the fitter periodically Cut the fuel line to a suitable length during installation Ensure that the fuel line joint surfaces a...

Page 15: ...thout the consent of the manufacturer The instructions for installation operation or maintenance have not been followed Storage or transport has been inappropriate A problem has resulted from an accid...

Page 16: ...WALLAS 40D Operator s Manual and Installation Guide 16 June 2 2010...

Reviews: