![background image](http://html1.mh-extra.com/html/wallas/800-d/800-d_technical-information_3230691063.webp)
5 l
2024
10 l
30 l
130 l
2027
4030
4130
200 x 300 x 130 mm
380 x 195 x 210 mm
590 x 200 x 300 mm
800 x 400 x 600 mm
en
Installation
Fuel connections
Things to note about the connections
The standard length of the fuel hose is 4 m (max 8 m) 13’ (max 26’). Cut the fuel
hose to a length suitable for installation.
The lift height of the pump should be less than 2 m (7’); preferably 0.5 – 1 m.
The fuel pipe must always have a Wallas fi lter. The fuel fi lter can be installed
either near the device, near the tank, or in another location where it can be easily
checked and replaced, when necessary.
Diesel engine fuel fi lters and/or separators are not approved for use. All soft con-
nections should be made with rubber or silicone hose which is resistant to diesel.
Country-specifi c requirements
The standard fuel hose is plastic. Please observe country-specifi c requirements
with regard to the material of the fuel hose/pipe and the fuel fi lter. The inner diam-
eter of a new replacement hose should be equal to the inner diameter of the plastic
hose. Copper pipe and metal fi lters are available as accessories.
Fuel feed
If the lift height exceeds 2 m, the fuel feed must be checked and, if necessary, ad-
justed. The fuel feed must also always be checked, if parts of the fuel system, such
as the pump or the electronics card, have been replaced.
Fuel system adjustments are device specifi c. These adjustments should only be
carried out by an authorized service shop.
Connection to a fi xed tank
The device must have a separate connection as well as a fuel fi lter outside the
tank.
Connection to a separate tank
Cap run-throughs and sintered fi lters are used on plastic tanks.
The fuel tank should be mounted securely.
The fuel tank should be placed close to the keel line.
The fuel connections must be tightened fi rmly so that the air cannot
leak into the hose. Always check the cleanliness of the connection
surfaces before tightening. Air leaks in the fuel system will cause the
device to malfunction.
(accessory)
(accessory)
(accessory)
(accessory)
Volume length x height x width
Order code
Wallas fuel tanks
en
D10111
- 63 -
490548
800 D
Summary of Contents for 800 D
Page 36: ...fi Asennus fi D10310 36 490548 800 D ...
Page 38: ...Asennus fi fi D10190 38 490548 800 D ...
Page 40: ...fi Asennus fi D10130A 40 490548 800 D ...
Page 72: ...en Installation en D10311 72 490548 800 D ...
Page 75: ...Installation en en D10321 75 490548 800 D ...
Page 76: ...en Installation en D10131A 76 490548 800 D ...
Page 108: ...sv Installering sv D10312 108 490548 ...
Page 112: ...sv Installering sv D10132A 112 490548 ...
Page 144: ...de Einbau de D10313 144 490548 800 D ...
Page 148: ...de Einbau de D10133A 148 490548 800 D ...
Page 180: ...fr Installation fr D10314 180 490548 800 D ...
Page 184: ...fr Installation fr D10134A 184 490548 800 D ...
Page 216: ...nl Installatie nl D10315 216 490548 800 D ...
Page 220: ...nl Installatie nl D10135A 220 490548 800 D ...
Page 252: ...ru Установка ru D10316 252 490548 800 D ...
Page 256: ...ru Установка ru D10136A 256 490548 800 D ...
Page 288: ...no Installering no D10318 288 490548 800 D ...
Page 292: ...no Installering no D10138A 292 490548 800 D ...
Page 306: ...D90019 306 490548 800 D ...