![wallas 800 D Technical Information Download Page 85](http://html1.mh-extra.com/html/wallas/800-d/800-d_technical-information_3230691085.webp)
en
Maintenance
Troubleshooting, locking indication
RELEASING THE LOCK:
1. When the lights are blinking, switch off
the main power at the battery (we
recommend removing the fuse), breaker or
in-line switch.
2. Switch the main power back on.
3. Press the power switch (for at least 2 s).
The yellow power indicator will light for 1-3
seconds.
4. When the yellow power indicator light has
gone out, press the power switch again (for
at least 2 seconds). The heater is turned off.
5. Restart the heater normally.
5.2.1_en
The device locks itself after 2
unsuccessful starts.
If the heater has locked itself, you must
determine the cause for the locking before
releasing it.
The fuel line is empty.
Follow the fuel flow. You can
follow the movement of the fuel
through the translucent fuel line.
The fuel line is full.
The fuel pump does not pump
fuel.
The piston of the fuel pump is
blocked.
The piston makes weak ticking
sound/vibration when it’s moving
normally.
Knock the body of the pump to
get the piston to move again.
The filter is blocked.
Change the filter to a new one.
Bad quality fuel.
Wrong fuel.
Change the fuel
Water in the fuel.
Clean the fuel and add the anti
ice agent according the
instructions of the supplier.
Bring the device in for service.
The glow plug has too weak
effect.
The fuel needle is blocked.
The burner is filled with crust.
There is a strong wind
pressure coming into the lead-
through.
Air leakage in the fuel system.
Tighten the connectors of the fuel
system.
The fuel has not reached the
burner yet.
Check the possible overflow of
the burner!
If there are several starting
attempts without successful start,
the burner may overflow.
Locking indication
FAULT INDICATION WITH
BLINKING LIGHTS
Yellow
Red
en
D20111
- 85 -
490548
800 D
Summary of Contents for 800 D
Page 36: ...fi Asennus fi D10310 36 490548 800 D ...
Page 38: ...Asennus fi fi D10190 38 490548 800 D ...
Page 40: ...fi Asennus fi D10130A 40 490548 800 D ...
Page 72: ...en Installation en D10311 72 490548 800 D ...
Page 75: ...Installation en en D10321 75 490548 800 D ...
Page 76: ...en Installation en D10131A 76 490548 800 D ...
Page 108: ...sv Installering sv D10312 108 490548 ...
Page 112: ...sv Installering sv D10132A 112 490548 ...
Page 144: ...de Einbau de D10313 144 490548 800 D ...
Page 148: ...de Einbau de D10133A 148 490548 800 D ...
Page 180: ...fr Installation fr D10314 180 490548 800 D ...
Page 184: ...fr Installation fr D10134A 184 490548 800 D ...
Page 216: ...nl Installatie nl D10315 216 490548 800 D ...
Page 220: ...nl Installatie nl D10135A 220 490548 800 D ...
Page 252: ...ru Установка ru D10316 252 490548 800 D ...
Page 256: ...ru Установка ru D10136A 256 490548 800 D ...
Page 288: ...no Installering no D10318 288 490548 800 D ...
Page 292: ...no Installering no D10138A 292 490548 800 D ...
Page 306: ...D90019 306 490548 800 D ...