Operation
After installation or maintenance, if the fuel line is empty, the device
may not start at the first attempt. If this is the case, the red combus
-
tion indicator light will start to blink roughly 4.5 minutes after start-
up.
Press the power switch to the OFF position. The device cannot be
restarted until the cooling phase has completed.
When it has cooled, switch the device on again.
If the device does not start after two attempts, it cannot be started
again: the device will lock down (lights blink to indicate this).
Release the lock (instructions in the maintenance section)
Depending on the length of the fuel hose, the device may have to be
started up several times. Keep an eye on how the fuel travels in the
fuel hose while starting up the device.
First start-up
After the heater has been started up, the power can be adjusted step-less with
the power adjustment knob (2). Avoid turning the adjustment knob back and forth
rapidly, as this can cause the burner to become sooty.
To end manual operation, turn the device off and restart it after allowing it to cool
normally.
Shutdown
You can shut down the heater by pressing the power switch (3) in continuously for
at least 2 seconds. The yellow current indicator light (4) will go out immediately.
The red combustion indicator light (1) will continue to blink for ca. five minutes,
while the device is cooling down. You cannot restart the device until the combustion
light has stopped blinking.
Remote control
The device can be controlled manually with an accessory, which can be purchased
separately.
If the device is started using the remote control, the orange indicator light (5) on the
control panel will blink at 10-second intervals. The sun-switch is not enabled in this
mode.
Do not start the device, while the battery is being recharged from a
generator unit or a battery charger (risk of overvoltage).
Cleaning and maintaining the device
To keep the device easy to use and looking good, clean it regularly. Wipe the de-
vice with a moist cloth and dry it with another cloth. Do not use abrasive cleaning
sponges or agents. Also, avoid chemically strong cleaning agents.
Regularly vacuum the back of the device. Dust easily collects at the back of the
device, and the airflow created by the device will spread the dust all over the room.
Observe the general maintenance recommendations for Wallas equipment when
servicing the electronic and mechanical parts of the heater.
Never use the main switch to cut the power before the cooling
phase, which starts after device is turned off, is completed.
en
26CC / 40CC
D80151
- 53 -
490525C