Device use 

Normal use

Temperature is controlled by the thermostat (recommended use).

The device starts when the power switch (3) is pressed in continuously for at least 

2 seconds, after which the yellow current indicator light (4) lights to indicate that the 

power is on. 

The red combustion indicator light will be lit, when the burner flame has been 

ignited and combustion has stabilised after ca. 2.5-4 min from when the heater was 

turned on.

After the heater has been turned on, you can adjust the thermostat setting using 

the temperature control knob (2). Turn the knob to set the temperature to your 

desired setting.

When the thermostat indicator light (5) is lit, the temperature in the space to be 

heated is lower than the requested temperature and the device is increasing the 

power. When the indicator (5) goes out, the requested temperature has been 

reached.

The sun-switch shuts down the device automatically, if the temperature rises above 

the requested temperature, for example, due to sunlight. The temperature must 

rise by +3 °C above the set value for a half an hour. If the device has been shut 

down by the sun-switch, an indicator light (5) blinks on the thermostat. The sun-

switch can be turned off temporarily, by turning the temperature control (2).

A device that has been shut down can be restarted manually, if necessary.

Conservation temperature: the temperature control (2) is set to minimum, and the 

room is maintained at a temperature of +2–+8 °C. The sun-switch is not enabled in 

this mode.

Alternative use

The power is adjusted manually.

To enable this function, turn the power adjuster (2) to positions min - max - min 

- max within 10 seconds of the yellow indicator (4) lighting up, during the device 

start-up.

The device signals that the function has been activated by blinking the thermostat 

indicator light (5) three times.

You can check whether or not the function is in use by turning the power adjuster 

(2): the thermostat indicator light should not light up at any point.

1. 

Combustion indicator

2. 

Temperature adjustment / Power 

control

3. 

Power switch

4. 

Current indicator

5. 

Thermostat indicator

6. 

Thermostat sensor

Operation

Colour

Blink interval

Function

Yellow

Red

Red

Power on

Combustion indicator when the com-

bustion has begun normally

Aftercooling

Thermostat control

Orange

Orange

Manual power control engaged

Device in remote control mode

Sun switch has shut down the device

Orange

Orange

Device in remote control mode

Orange

en

Signal lights

26CC / 40CC

D80151

- 52 -

3

1

2

10 s

30 s

10 s

10 s

10 s

10 s

10 s

10 s

10 s

1

2

5

6

3

4

M40_M26.indd   1

19.06.2008   14:47:49

1.

2.

3.

4.

5.

6.

490525C

Summary of Contents for 26CC

Page 1: ...l tank 30 l Fuel tank 10 l Combustion air pipe 45 mm Al Exhaust pipe 50 45 mm stainless Protection tube 0 5 m fuel hose Control panel cable 6 m Extension line 2 m Fuel tank 130 l Insulating channel In...

Page 2: ...ntenance instructions Fuel tank connection Short circuit connector for mountain switch 1 pcs 1 pcs 1 pcs Accessory bag 260941A 1 pcs Heater without front panel Control panel package 361061A Fuel hose...

Page 3: ...n air blower are fully stabilised against voltage fluctuations which ensures clean combustion regardless of changes in the battery voltage The heater is equipped with built in overheat protection whic...

Page 4: ...Technical information Operating principles en 26CC 40CC D80151 40 P 12 V 490525C...

Page 5: ...the device near to an external door or a window because the temperature changes in these loca tions are too great The control panel contains a thermostat sensor Flue installation will slightly increa...

Page 6: ...st be unobstructed There must be no surfaces structures or objects that are flammable or can obstruct the heat within 1 m above the device s upper surface Safety distances Device over 1300 m above sea...

Page 7: ...pipe s connection 26 with a hose binder 10 Both ties can be found in the heater accessory bag The exhaust pipe cannot be tightened suf ficiently by any other fastening than a pipe clamp 11 which must...

Page 8: ...4 items 4 5x25 The lid of the flue gas exhaust head 15 must be opened before installation screw 31 Ensure that the ends of the hoses 23 and 24 extend to the limiters 32 and 33 18 Finally fasten the h...

Page 9: ...allation Picture 1 Installation in Finland Installation in Sweden and Norway 320 mm insulation en 26CC 40CC D80151 45 26 25 23 16 17 15 32 33 29 24 21 18 20 31 10 12 11 28 70 mm 100 mm sv no 19 27 490...

Page 10: ...fter you connect the power cord and the fuel hose Note If you choose to lead in the combustion air from under the floor ensure there is suf ficient ventilation in the foundations beneath the floor Ins...

Page 11: ...direct current system Connect the red wire of the power cord to the plus terminal of the battery and the black or blue wire to the minus terminal A 15 A main fuse must be installed near the battery o...

Page 12: ...adjustments are device specific We recommend that the adjustment be carried out by an authorised service shop Tank placement 1 The fuel tank should always be placed below the base of the device The fu...

Page 13: ...cap Bleeding hose Bayonet coupling Bayonet coupling Cap run throughs The fuel connections must be tightened firmly so as to not allow air to leak into the hose Always check the cleanliness of the con...

Page 14: ...must not fall below 40 C If the temperature drops lower than the minimum level paraffin may form in the fuel This may result in the fuel filter and pump being clogged The clog will dissolve only if t...

Page 15: ...cottage is outside the GSM network coverage The weekly timer starts up and shuts down the heater at the times you select Timer cable 4205 For use with weekly timer 4206 Solenoid valve 30017 The soleno...

Page 16: ...ed off temporarily by turning the temperature control 2 A device that has been shut down can be restarted manually if necessary Conservation temperature the temperature control 2 is set to minimum and...

Page 17: ...s The yellow current indicator light 4 will go out immediately The red combustion indicator light 1 will continue to blink for ca five minutes while the device is cooling down You cannot restart the d...

Page 18: ...or the dosage observe the recommendations provided by the manufacturer of the agent Maintenance An anti freezing agent for diesel vehicles may increase the forming of scale at the bottom of the burner...

Reviews: