Jointing
A jointing should only be made in long
power cords, if necessary, in which
case the cord must be replaced with
a thicker one. The jointing cannot be
further than 1 meter from the device.
Electrical connections
Things to note about the connections
The device uses 12 V direct current voltage. To minimise current losses, make the
power cable as short as possible and avoid jointing. The cross-sectional area of the
cable is dependent on the length of the power cord. The cross-sectional area of the
cable must be consistent all the way from the stove to the battery. The maximum
length of the power cord is 10 m.
Electrical connections of the device
12 V direct current system
Connect the red wire of the power cord to the plus terminal of the battery and the
black or blue wire to the minus terminal. A 15 A main fuse must be installed near
the battery on the red plus wire of the power cord.
Checking the connection
The device consumes most power when it is started up (glowing). At this point volt-
age losses are also at their highest. During the glowing phase, the voltage must be
at least 10.7 V measured at the quick coupling. If the voltage is lower than this, the
device may not start.
Princible diagram of the electrics.
Installation
Total length of the power cord (m)
Cross-sectional are of the cable (mm
2
)
If a thicker cable is required, make a separate joint in the power cord.
Device’s quick
coupling
Main fuse
Power cord
en
The cross-sectional area of the cable
26CC / 40CC
D80151
- 47 -
0 - 4
4 - 6
6 - 10
4
6
10
490525C