37
Functions of the luminaire
ENG
Key on the multi-
function pushbutton
Ke y o n t h e
sensors
Upper key
I
Lower key
II
Tab. 4: Correspondence of the keys.
The table Tab. 4 „Correspondence of the
keys.“ shows which key on the multifunc-
tion pushbutton corresponds to which key
on the sensors. For example, the upper
key on the multifunction pushbutton cor-
responds to key
I
on the sensors.
These instructions for use describe the
operation of the light using the multifunc-
tion pushbutton.
7.2 Switching on and off
When switching on a luminaire with LUM
CONNECT MANAGE light management,
indirect light and direct light are switched
on with a time delay. The light control is
adjusted automatically to the reflection con-
ditions of the room.
Switching VTL on and off
X
Press the upper switch, siehe Fig. 19
If you switch VTL on, the luminaire con-
trols the colour temperature and the
illuminance of the indirect light in the
course of the day.
If you switch VTL off, it does not have
any direct effect on the direct light. The
light control remains activated. LUM
CONNECT MANAGE controls the inten-
sity of the direct light if the intensity in
the detection range of the daylight sen-
sor has changed. The automatic switch-
on and -off of the luminaire also remains
activated depending on the intensity in
the room. The luminaire switches off
automatically if the intensity of the day-
light is sufficient.