background image

Thank you for purchasing Wakespeed Offshore’s Model WS100/12 Multi-
Stage Voltage Regulator. Designed by Michael Frost, one of the pioneers of 
smart, multi-stage battery charging systems, the Wakespeed WS100/12 
voltage regulator provides optimal care for your batteries, when used in 
conjunction with a P-type, externally regulated alternator.

The WS100/12 was designed specifically to provide the user with an ex-
tremely simple interface — only two adjustments are required to deliver 
tailored  charging  to  your  batteries.  A  convenient  five-position  rotating 
switch enables the user to select one of five programs based on battery 
type:  standard  flooded/gel,  standard  AGM,  Carbon  Foam,  deep  cycle 
flooded and high-density AGM/TPPL.

In addition to the selectable programs for battery type, the WS100/12 
provides the ability to adjust the maximum regulator field output, making 
it possible to reduce alternator horsepower load to the engine and belt. 
Four  settings  are  available:  100%  (no  field  reduction),  90%,  75%  and 
50% field output.

The WS100/12 can be used alone, or in conjunction with optional WS-
100-ATS and WS-100-BTS alternator and battery temperature sensors. 
With the temperature sensors installed, the WS100/12 can monitor and 
respond to changes in ambient battery temperatures and reduce charging 
output if the alternator temperature exceeds safe operating temperatures.

WS100/12 Product Manual

Page 1

Summary of Contents for WS100/12

Page 1: ...ive programs based on battery type standard flooded gel standard AGM Carbon Foam deep cycle flooded and high density AGM TPPL In addition to the selectable programs for battery type the WS100 12 provides the ability to adjust the maximum regulator field output making it possible to reduce alternator horsepower load to the engine and belt Four settings are available 100 no field reduction 90 75 and...

Page 2: ...n field output as well as providing the regulator with sensing voltage The Power Wire must be fused at 10 amps An ATC type fuse holder and 10A ATC fuse are included with the regulator and must be installed at the source of power at the alternator or battery end of the wiring harness Possible connection locations for the RED Power Wire include 1 The positive output post of the alternator recommende...

Page 3: ...ge whenthe ignition switch is on and the engine is running recommended 2 The ON side of an oil pressure switch BLUE FIELD Wire The BLUE field wire in the regulator s wiring harness provides field current to the alternator s positive brush which enables the regulator to control excitation and alternator output The BLUE field wire is connected to the field terminal of an externally regulated P type ...

Page 4: ...ry temperature potential thermal runaway at batteries The Dash Lamp wire can be connected to the negative ground side of a user installed warning lamp or audible alarm Page 4 optional temperature sensor cables When used in conjunction with its optional temperature sensor cables the WS100 can use ambient temperatures at the batteries and at the alternator to provide additional safety and charging e...

Page 5: ...ery bank In addition to enabling the regulator to adjust for ambient battery temperature the Battery Temperature Sensor will enable the regulator to shut down if battery temperature exceeds safe levels 125 F NOTE Do not install or remove battery or regulator temperature sensor cable while regulator is activated GREEN ALTERNATOR Cable The WS100 12 Alternator Temperature Sensor cable enables the vol...

Page 6: ...ogram 1 Standard Flooded Gel Designed to properly charge standard thin plate flooded and gel battery types See chart on Page 6 for specific charging voltage values Program 1 is indicated by the far left green light marked 1 Program 2 Standard Absorbed Glass Mat Program 2 provides proper charging voltages for many common AGM type batteries See chart on Page 6 for specific charging voltage values Pr...

Page 7: ...ted Program 5 High Density Absorbed Glass Mat TPPL Program 5 provides proper charging voltages for high density AGM type and TPPL Thin Plate Pure Lead batteries See chart on Page 6 for specific charging voltage values Program 2 is indicated when 1 and 2 green lights are illuminated Time and voltage settings for each battery program are detailed at the end of this instruction book Be sure to consul...

Page 8: ...output provided by the regulator Limits will be indicated as follows 1 100 Field Indicated by no RED lights on the regulator next to codes indicated by A B or C on the regulator s label 2 90 Field Indicated by the RED light illuminated by the letter A on the regulator s label 3 75 Field Indicated by the RED light illuminated by the letter B on the regulator s label 4 50 Field Indicated by the RED ...

Page 9: ... target voltage for float the regulator will monitor the field pulse width If the maximum float pulse width cannot maintain the target voltage for float charging the regulator will return to acceptance charging voltage During extended engine operation and under varying battery loads the voltage may cycle between charge modes multiple times Operational Display During normal operation the regulator ...

Page 10: ...num Alloy Dimensions 4 7 8 x 2 5 8 x 1 Display Color coded LED 8 Circuit Protection Conformal Coating Regulator Program Values Prog Battery Type Bulk Volts Acceptance Volts Float Volts Fixed Time Flex Time Min Float Time Max Temp Comp mV C 1 Std FLA Gel 14 1 13 9 13 4 18m 18m 120m 24 2 Std AGM 14 38 14 18 13 4 18m 18m 120m 24 3 Carbon Foam 14 4 14 2 13 4 18m 18m 120m 24 4 Deep Cycle FLA 14 6 14 4 ...

Page 11: ...harnesses or items damaged in shipment in route to Wakespeed Warranty Services for repair Thomason Jones Company Wakespeed assumes no responsibility for consequential damage or loss or expense arising from these products or any labor required for service or repair Wakespeed will not repair or be held responsible for any product sent without proper identification and return address or Return Author...

Page 12: ...Page 12 NOTES For more information visit www wakespeed com Or call Wakespeed Support at 360 299 1231 Or email support wakespeed com Wakespeed Offshore PO Box 1541 Anacortes WA 98221 ...

Reviews: