WS100/12 Product Manual
Regulator Wiring
oRange (DaSH laMP) wiRe —
The ORANGE Dash Lamp circuit is designed to provide a source of
ground to complete a circuit at a warning light or audible alarm if one
of the following conditions exists: low system voltage (alternator is not
charging properly), high system voltage (alternator is charging above safe
voltage), high alternator temperature (requires alternator temperature
sensor), high battery temperature (potential thermal runaway at batteries).
The Dash Lamp wire can be connected to the negative (ground) side of a
user-installed warning lamp or audible alarm.
Page 4
oPtional teMPeRatuRe SenSoR CaBleS
When used in conjunction with its optional temperature sensor cables,
the WS100 can use ambient temperatures at the batteries and at the
alternator to provide additional safety and charging efficiency. Connection
for temperature sensor cables is provided via built-in RJ45 terminals at
the bottom of the regulator.
WS100-BTS-KIT — Battery Temperature Sensor Cable (BLUE)
WS100-ATS-KIT — Alternator Temperature Sensor Cable (GREEN)