background image

 
All Waikato Milking Systems are fitted with top quality rubberware or PVC tubing.  Good 
cleaning will lengthen the life of these products so be sure to follow the cleaning 
instructions of the manufacturers. 
 
Waikato Milking Systems’ proprietary range of liners all have a useful life of 2500 cow 
milkings. 
 
Generally, change liners and milk pump diaphragms twice a season, long milk tubes 
(including the bend at the milk line end of the stainless steel tube)  and long pulse tubes 
once a season, and short pulse tubes as required. 
 

AUTOMATIC CLUSTER REMOVERS 

 
Consult your Waikato Milking Systems dealer for support information if your new milking 
machine is fitted with automatic cluster removers. 
 

MILKING MACHINE TESTING 

 
Waikato Milking Systems NZ Ltd and Waikato Milking Systems dealers recommend that 
your milking system is tested twice each season by a registered milking machine tester.  
Contact your dealer for more information. 

 

7

Summary of Contents for Rotary Loopline

Page 1: ...9860110 2002 WAIKATO MILKING SYSTEMS NZ LIMITED 558 Te Rapa Rd P O Box 20055 Hamilton New Zealand Telephone 07 849 8755 International 64 7 849 8755 Facsimile 07 849 0164 International 64 7 849 0164 ww...

Page 2: ...g Systems proprietary components on your milking machine are covered by a 12 month warranty or you may have accepted an extended warranty program which looks after your Waikato Milking System for two...

Page 3: ...the controller to AUTOMILK will also open the milk line valve The plant vacuum will rise and milking can begin WASHING With the machine at full vacuum 1 Place all clusters into the cluster washers 2...

Page 4: ...uum pump s 8 Remove the clusters from the cluster washers The minimum wash water requirements for your Waikato Rotary Loopline are Hot Water 10 litres per cluster Cold Water 15 litres per cluster Waik...

Page 5: ...give consistent performance over a wide range of vacuum levels Like all vacuum regulators it can be affected by dust and dirt and its filter should be cleaned at least once a week by removing it and w...

Page 6: ...and when they wear out Air leaking past the rubber cups will adversely affect the wash cycle VALVE SEALS Your Waikato Rotary Loopline has one main milk line valve and one jetter suction valve which c...

Page 7: ...ason long milk tubes including the bend at the milk line end of the stainless steel tube and long pulse tubes once a season and short pulse tubes as required AUTOMATIC CLUSTER REMOVERS Consult your Wa...

Page 8: ...short and long pulse and milk tubes and liners Replace any items which have been holed or split Sanitary trap Check for milk residues Clean both the sanitary trap and the receiver air line if residue...

Page 9: ...unions and tighten if necessary Check claw seals shut off valves and buttons and bowls Replace if necessary Open the cooler inspect each plate and clean if necessary TWICE A SEASON Change liners milk...