WAIKATO
ROTARY LOOPLINE OPERATION
The
Waikato
Rotary Loopline
is designed for easy operation.
MILKING
1.
Open
the valve on the milk line.
2.
Close
the air injector valve.
3.
Make sure the air injector is turned
off
.
4.
Make sure the snap clamp on the rubber tube connecting the sanitary trap to the
receiver suction line is
closed
.
5.
Insert the plug into the interceptor.
6.
Start the vacuum pump/s.
7.
Switch the milk pump controller to
“AUTOMILK”
. (If a
Waikato
Flow Control
System is fitted, switching it to AUTOMILK will automatically turn off the air
injector. If a valve actuator is fitted, switching the controller to AUTOMILK will
also open the milk line valve.
The plant vacuum will rise and milking can begin.
WASHING
With the machine at full vacuum
1.
Place all clusters into the cluster washers.
2.
Close
the milk line valve/s.
3. Turn
on
the air injector/s.
4.
Open
the air injector valve.
5.
Open
the snap clamp on the rubber tube connecting the sanitary trap to the
receiver suction line.
6.
Switch the milk pump controller to
“WASH”
. (If a
Waikato
Flow Control System
is fitted, switching it to WASH will automatically turn on the air injector. If a valve
actuator is fitted, switching the controller to WASH will also close the milk line
valve.
7.
Open
the valve at the wash tub.
8.
Do not start recycling washing solutions until at least 20 litres have been run to
waste.
The machine will now wash.
3