352-353.805.006
18
Date: 2019-07-02
Mode setting
The mode switch is found on the front panel left to the DMX address switches and this can be
used to select various functions and ramps for normal operation and setup.
Mode setting overview
MODE Function
Description
Note
0
None
Track Runner is stopped.
1
None
2
Manual down slow
Manually run reverse (moving to the left seen
from the connection side), as for installation
without DMX applied.
CAUTION! Manual
modes will overrule
any DMX control,
and movement of
the motor may only
be interrupted by
powering off the
mains voltage.
3
Manual down fast
4
Manual up slow
Manually run forward (moving right see from
the connection side), as for installation
without DMX applied.
5
Manual up fast
6
None
Track Runner is stopped.
7
DMX slow position ramp
For normal operation of the unit, and the
slow, medium or fast ramps may be selected
depending on the use and the type of load.
8
DMX medium position ramp
9
DMX fast position ramp
DMX ADDRESS setting and channel overview
The DMX address, also known as the start channel, is the first channel used to receive instructions
from the controller. For independent control, each unit must be assigned its own control channels.
The DMX address is configured using the three DMX ADDRESS selectors on the unit. The selected
DMX address states from which channels, on the lighting desk, the unit is controlled. The unit uses
6 DMX channels. The example below shows a DMX start address 212 (200+10+2).
Summary of Contents for 352.701