WAGO-SPEEDWAY 767
Device Description
29
767-5803/000-800 8DIO 24V DC 0.5A IF (8xM12)
Manual
Version 1.1.0
3.7.11 Configurable functions for counters
Table 18: Technical data – Configurable functions for counters
Counter mode
- Event counter
- Gate time measurement
- Pulse duration counter
Gate time basis
- 1 ms
- 10 ms
- 100 ms
- 1 s
- 10 s
Gate, Configuration via ...
- Process data
- Digital input
Gate
- Enabled
- Disabled
Count direction, Configuration
via ...
- Process data
- Digital input
Count direction
- Forward
- Backward
Allow counter overwrap
(jump from 65535 -> 0 or from 0 ->
65535)
- Disabled
- Enabled
Counter start value / limit value
Value: 0 … 65535
Set start value/limit value
Count direction forward:
Set counter value to 0. Limit
value is to be specified.
Count direction backward:
Start value is to be specified
Set value
Limit value output
Count direction forward:
Limit value output is set active
upon reaching the counter value
"Limit value"
Count direction backward:
Limit value outoupt is set active
upon reaching the counter value 0
- Do not use
- Use
Limit value reset
Count direction forward:
Set counter value to 0 upon
reaching limit value
Count direction backward:
Set counter value to start value at
counter value 0
- Disabled
- Enabled
Counter reset
(when limits are exceeded)
- Disabled
- Enabled