background image

30 •

Accessories

Fieldbus Dependent I/O Module

PROFIBUS DP

8  Accessories

Accessories

Article No.

Pcs. per packing unit

Type and GSD files (floppy disk)

750-910

1

Marking label 16 DI/16DO

752-102

1 sheet (9 labels)

Replacement fuse F1 (TR 5 / 250 V / 6.3A T)
Micro-fuse according to IEC 127-3

Note: 

Use UL-Recognized fuse only

752-180

5

Felt tipped pen for non-smudge writing

210-110

1

Operating tool (screw driver)
- Blade (2.5x0.4) mm
- Blade (3.5x0.4) mm

- with part. insulated shank, blade (2.5x0.4) mm
- with part. insulated shank, blade (3.5x0.4) mm

210-119
210-120

210-619
210-620

1
1

1
1

Summary of Contents for 752-323

Page 1: ...Fieldbus Dependent I O Module PROFIBUS Manual Technical Description Installation and Configuring 752 121 000 002 Version 1 0 0...

Page 2: ...h 49 0 571 8 87 5 55 Fax 49 0 571 8 87 4 30 E mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can nev...

Page 3: ...Module 11 4 1 2 Insertion Extraction of the Electronic Module 12 4 1 3 Marking Label 12 4 1 4 Station address 13 4 2 Electrical Installation 13 4 2 1 General 13 4 2 2 Connection of the Module Supply V...

Page 4: ...Review 25 7 2 GSD files 25 7 3 Parameterization 26 7 4 Configuration 26 7 5 Diagnosis 27 7 6 Process Data Image 28 7 6 1 Process Data Input Image 29 7 6 2 Process Data Output Image 29 7 7 Fieldbus Co...

Page 5: ...rred to without reference to patent rights For this reason the existence of such rights cannot be excluded 1 1 2 Personnel Qualification The use of the product described in this manual is solely inten...

Page 6: ...n in all cases to protect the system from damage Attention Marginal conditions to be observed in all cases to ensure a troublefree opera tion ESD Electrostatic Discharge Warning of danger to the compo...

Page 7: ...DIx Digital input x DOx Digital output x DSx Diagnostic status for the output group x GSD Ger testammdaten master file of devices PNO PROFIBUS Nutzerorganisation e V User Organisation RTS Request To S...

Page 8: ...eldbus connection Power supply terminal blocks for internal electronic and external sensors Sensor signal DI Sensor supply Release clip 0V Aktuator signal DO Actuator Supply 0V PROFIBUS RUN BF OVERLOA...

Page 9: ...T I OUTPUT O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 0V 24V Fig 2 2 Base Module g1x2306x Fieldbus connection 9 pole D SUB Module power supply terminal bl...

Page 10: ...allation into the base module If a replacement of the electronic module is necessary the wiring remains undisturbed Status indicators for fast diagnostics The electronic module includes a marking labe...

Page 11: ...voltage DC 24 V 15 20 Current input module without load 100 mA for 24 V DC Total loss of power 4 5 W Fuse F1 for sensor supply TR5 250 V 6 3A T General information Dimensions W x H x L 155 x 129 x 60...

Page 12: ...nt 2 mA Short circuit protection electronic automatic restart Max operating frequency without bus resistive load inductive load 1 kHz utilization category DC 13 equals 6 Hz Insulation electronics fiel...

Page 13: ...inspection Fc 10 57 Hz constant amplitude 0 075 mm 57 150 Hz constant acceleration 1 g Impact According to IEC 60068 2 27 15 g 11 ms Electrical Safety Reverse voltage protection Yes Air and creepage...

Page 14: ...16 33 33 34 34 35 35 36 36 37 37 38 38 39 39 40 40 41 41 42 42 43 43 44 44 45 45 46 46 47 47 48 48 0V 0V 24V 24V PROFIBUS PROFIBUS READY READY BF BF OVERLOAD OVERLOAD PUSH PUSH PUSH PUSH WAGO I O SYS...

Page 15: ...6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 17 18 25 26 WAGO I O SYSTEM 752 PROFIBUS 16 DI 16DO ITEM NO Fertigungsnr 13...

Page 16: ...ng in the electronic module g1x2302x The electronic module is correctly inserted when all four latches have en gaged PROFIBUS RUN BF OVERLOAD PUSH PUSH WAGO I O SYSTEM 752 16DI 16DO 752 323 01 2 3 4 5...

Page 17: ...unpermissible address 0 the station use the address 126 The station address is taken over by the I O module after power on Changes during the operation have no effect 4 2 Electrical Installation 4 2 1...

Page 18: ...42 43 44 45 46 47 48 17 18 25 26 WAGO I O SYSTEM 752 PROFIBUS 16 DI 16DO ITEM NO Fertigungsnr 1300 07 04 752 823 INPUT I OUTPUT O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 33 34 35 36 37 38 39 40 41 42 4...

Page 19: ...e terminals are available for each digital input The termi nals for one input are shown superimposed 1 2 3 17 18 19 33 34 35 24 V 0 V Input grey Color red blue Supply of the field devices Vertical con...

Page 20: ...shipped with jumpers installed in each of these termi nals connecting 24VDC module power to connection point for the output supply voltage 24 V 0 V 1 2 3 33 34 35 4 5 6 7 8 17 18 36 37 38 39 40 Output...

Page 21: ...the terminal blocks This row of terminal blocks will be wired back to the source common of the supply potential 4 2 5 Connection of the Output Signals The output signal terminals are identified by the...

Page 22: ...ed and screened pair of wires The fieldbus line is specified in EN 50 170 as a line type A and must provide certain line parameters The line type B also described in the EN 50 170 is an old type and s...

Page 23: ...an be maximum 16 mm 6 6 3 3 1 1 9 9 8 7 2 2 4 4 7 8 5 5 VP 390 390 220 RxD TxD P RxD TxD P RTS RTS RxD TxD N RxD TxD N DGND 9 pole D SUB Connector with Terminating Resistor 9 pole D SUB Connector Furt...

Page 24: ...2 PROFIBUS 16 DI 16DO INPUT I INPUT I INPUT I INPUT I OUTPUT O OUTPUT O OUTPUT O OUTPUT O PROFIBUS DP PROFIBUS DP PROFIBUS DP PROFIBUS DP RUN RUN BF BF OVERLOAD OVERLOAD WAGO I O SYSTEM 752 16DI 16DO...

Page 25: ...representation of the input output and supply circuitry are shown in the schematic circuit diagram 100nF 100nF 100nF 100nF 100nF 10nF 0 V 24 V 6 3 A DI 1 16 DO 1 16 DI DO Fieldbus connection Actuator...

Page 26: ...3 14 15 16 1 2 3 4 5 6 7 8 OUTPUT 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 3 1 2 Fig 6 1 Status Indicators g1x2305x 1 Fieldbus PROFIBUS specific status indicators...

Page 27: ...cuit OFF 1 No supply OFF 0 No supply OFF 1 Output switched on 0 Output switched off 6 3 Fieldbus Interface Status Indicators LED Color Status Meaning RUN Operational Green ON OFF The supply voltage is...

Page 28: ...tage to the output drivers Fault of an output driver Feedback A fault is detected if a transmitted value of 1 by the master controller does not produce a threshold voltage at a corresponding output Wh...

Page 29: ...ures of the modules are defined by the manu facturers in the form of a GSD file unit basic data Structure content and coding of this unit main data are standardised and made available to the user allo...

Page 30: ...6 Group allocation 7 0 0 0 0 0 WD 0 0 Watchdog Base 0 Time base 10 ms 1 Time base 1 ms 8 0 0 0 0 0 0 0 0 reserved ever 0 9 0 0 0 0 0 0 0 0 reserved ever 0 10 0 0 0 0 0 0 0 0 reserved ever 0 11 0 0 0...

Page 31: ...over Byte or word Total length 7 5 Diagnosis The slave diagnosis of the I O module provides 6 Byte standard diagnosis and 7 Byte device status diagnosis Byte Information Meaning 0 Station status 1 1 S...

Page 32: ...roduce a threshold voltage at a corresponding output When such a fault is detected the electronic module transmits a periphery fault signal to the fieldbus controller board and illuminates the OVERLOA...

Page 33: ...er board Fieldbus controller boards for programmable logical controls are available from other manufacturers 7 8 Configuration Software Before a PLC can communicate I O data with a fieldbus device the...

Page 34: ...O 752 102 1 sheet 9 labels Replacement fuse F1 TR 5 250 V 6 3A T Micro fuse according to IEC 127 3 Note Use UL Recognized fuse only 752 180 5 Felt tipped pen for non smudge writing 210 110 1 Operating...

Page 35: ...n of and access to the decentral fieldbus equipment It is the fieldbus master which co ordinates the bus traffic and transfers the data to a control system Group Input output group connection group Ge...

Page 36: ...WAGO Kontakttechnik GmbH P O Box 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Telephone 05 71 8 87 0 Telefax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Reviews: