2.4.1
CORRECT USE
2.4.2
EXPLOSION PROTECTION IDENTIFICATION
2.4.3
MAX. SURFACE TEMPERATURE
2.4.4
SAFETY REGULATIONS
2.4
USE IN AN EXPLOSION HAZARD AREA
4HEUNITISSUITABLEFORWORKINGLIQUIDMATERIALSINACCORDANCEWITHTHECLASSIlCATIONINTO
EXPLOSIONCLASSES
As defined in the Directive 94/9/CE (ATEX 95), the unit is suitable for use in areas where
there is an explosion hazard.
II 2G IIB T4
CE:
Communautés Européennes
Ex:
Symbol for explosion protection
II:
Unit class II
2:
Category 2 (Zone 1)
G:
Ex-atmosphere gas
IIB:
Explosion class
T4:
Temperature class: maximum surface temperature < 135°C; 275°F.
Max. surface temperature:
same as the permissible material temperature
Permissible ambient temperature:
see under Technical data, Section 4.3.2
Safe handling of WAGNER spray units
The maximum surface temperature of the pump can be reached if it runs dry.
Ensure that the pump is filled with sufficient working or cleaning medium.
Mechanical sparks can form if the unit comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the unit against steel or rusty iron.
Do not drop the unit.
Use only tools that are made of a permitted material.
Ignition temperature of the pumped material
Check that the ignition temperature of the pumped material is higher than
the max. allowable surface temperature.
Medium supporting atomizing
To atomize the material, use only weakly oxidizing gases, e.g. air.