36
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
6.7.1 ASSEMBLY OF HIGH-SPEED ROTARY ATOMIZER ON RECIPROCATOR
The high-speed rotary atomizer can flexibly be mounted.
The TOPFINISH Bell 1S can be mounted to a reciprocator with corresponding fastening
elements (see Chapter
The high-speed rotary atomizer has three lines for the media (product M, flushing agent FB
and return/circulation DM).
Cover dump outlets that are not used with corresponding valve plugs.
Connecting flange
Reciprocator
B_06672
Material needed:
a) Pre-assembled hose sets for product, air, high voltage and optical fiber (see Chapter
)
or
a) 4x air hose 4/2.7 mm, of appropriate length
1x air hose , 6/4 mm, of appropriate length
5x air hose 8/6 mm, of appropriate length
b) Pre-assembled high-voltage cable (high-voltage cable and connector plug) (see
Chapter
) of appropriate length
c) Optical fiber (see Chapter
)
d) Product line of the appropriate length
e) Dump line (waste line) of the appropriate length
f) Flushing agent line for flushing the bell plate of the appropriate length
Tools needed:
- Allen wrench, size 5, for socket cap screws for fastening on the reciprocator
- Allen wrench, size 3, for optical fiber
- Wrench, size 8, for product nozzle
- Wrench, size 12, for the hoses for product, dumping and flushing agent
- Teach tip (order no. 2393703)
- Socket (order no. 2396538)
Procedure
1. Move reciprocator into assembly position.
2. Fasten high-speed rotary atomizer to the mounting bracket using the mounting
rod.
3. The high-speed rotary atomizer is then connected with the hose set (see Chapter
) on the reciprocator or it is connected with lines suitable for product and air, as
described below.