52
Prima Sprint
.
P_01116
Tribo Corona
5
4
3
2
1
120
100
80
60
40
30
20
15
10
5
μA
μA
2x
kV
90
80
70
60
50
40
30
20
10
100
P_01123
OPERATING MANUAL
VERSION 07/2009
ORDER NUMBER DOC 2305835
6.5.8
SETTING THE U/I CHARACTERISTICS
32
31
Procedure:
To change the characteristic slope, press the
“characteristic slope“ button 31 once or twice until the
desired characteristic curve is shown in the “characteristic
slope“ LED display 32.
EPG SPRINT U/I characteristics
The user can choose from three characteristic curves to achieve optimum coating results.
These enable optimum electrostatic charging of the powder despite different powder
characteristics.
standard
medium
soft
High-voltage [kV]
100 kV
Spr
a
y curr
e
nt [µA]
120 [µA]
The properties of the various characteristic curves and their use are described on the
following page.
Summary of Contents for Prima Sprint 3L
Page 2: ......
Page 96: ...96 Prima Sprint OPERATING MANUAL VERSION 07 2009 ORDER NUMBER DOC 2305835...
Page 124: ...124 Prima Sprint OPERATING MANUAL VERSION 07 2009 ORDER NUMBER DOC 2305835...
Page 125: ...125 Prima Sprint OPERATING MANUAL VERSION 07 2009 ORDER NUMBER DOC 2305835...
Page 127: ......