31
VERSION 05/2019
ORDER NUMBER DOC2326960
PEM-X1 CG
24 Universal control dial
– Dynamic digital control dial with 32 positions per revolution
– Adjustment speed is proportional to rotational speed
– Used to set: "Total air volume; atomizer, ionizer and Tribo air; additional recipes;
High voltage; Current limitation; Powder quantity"
– For setting parameter values in configuration mode
25 Push button: "Additional recipes"
– To activate the function, the Additional recipes adjustment is set with the control
dial 24 and is indicated in the LED display 19.
– Selection of the recipes 5 to 50
26 LED display: "Additional recipes"
– Lights up yellow, when an additional recipe is selected
27 Push button "High voltage"
– To activate the function, the high voltage is set with control dial 24 and is indicated
in LED Display 19
– Adjusting range: 10–100 kV
– Resolution: 1 kV
28 LED display: "High voltage"
– Lights up yellow. The high voltage is selected and can be adjusted using control dial 24
29 Push button: "Current limitation"
– To activate the function, the current limitation is set with the control dial 24 and is
indicated in the LED display 19
– Adjusting range: 5–120 µA
– Resolution: 1 µA
30 LED display: "Current limitation"
– Lights up yellow. The current limitation is selected and can be adjusted using the
control dial (24).
31 Push button: "Characteristic slope"
– To switch the characteristic slope
– Display with LED 32
32 LED display: "Characteristic slope"
– Lights up green
– Lower LED characteristic curve, flat
– Middle LED characteristic curve, medium
– Upper LED characteristic curve, steep