Procedure:
1. Install the lower section Y of the suction wall with a crane or forklift.
2. Secure the lower section Y with at least 2 fl oor dowel bolt X to the fl oor.
3. Mount the silencer 1 to the exhaust system 2 and the screw both to the lower section
Y.
4. Insert the threaded bar 4 in the fi lter cartridge 3 and position both below the cartridge
opening.
5. Screw the threaded bar 4 into the cleaning nozzle and tighten it by hand.
6. Hold up the fi lter cartridge 3 and screw the sealing washer and washer 4/1 with the
star knob 4/1 onto the threaded bar 4.
7. Attach the defl ector grate 5 and defl ector 6.
8. Mount the side panels 7.
9. Mount the roof panels 8.
10. Align the spray wall and bolt it to the fl oor.
The powder coating system must be perfectly grounded for safety reasons.
Wagner recommends the usage of a copper cable of at least 16 mm² with adequate
mechanical strength.
t is important for system security and to achieve an optimum coating, that all system
components such as workpieces, conveyors, control unit, color supply, control unit and
booth or spray wall are perfectly grounded.
The imperfect grounding of a workpiece will result in:
●
Dangerous electric charging of the workpiece.
●
Very poor wrap-around.
●
Uneven coating.
●
Backspraying to the spray gun, i.e. contamination.
The prerequisites for perfect grounding and coating are:
●
Good grounding of the workpiece to be coated.
●
Grounding of the powder coating booth, transport and suspension equipment to
be provided on site, in accordance with the corresponding Operating manuals or the
defi nitions laid down by the manufacturer.
●
Regular cleaning of hangers from powder residues.
●
A grounding resistance for the workpiece of a maximum of 1 M
Ω
(mega ohm).
●
Grounding cable connected to the controller module or control cabinet.
If hooks or other hanger parts do not have all the paint removed, ignitable sparks
can occur between workpiece and hangers. These sparks can cause strong radio
frequency interferences.
5.4
GROUNDING
Summary of Contents for Basic 8000