iOnBoost™ V6 by Wagan Tech
®
10
10. Start vehicle engine. Stop if the vehicle does not start after 3 to 4 seconds of engine
cranking. Wait 3 to 4 minutes, then try again. If engine does not start after second attempt,
discontinue cranking and consult a professional.
11. When finished, disconnect the clamps in reverse sequence of connecting procedure—
first disconnect negative (black), then positive (red) clamps. Do not let the clamps touch
each other.
12. Disconnect the jumper cable assembly from the unit.
13. When convenient, using either AC or DC charging adapter, completely charge the
iOnBoost battery.
14. Store the unit and charge adapters in a cool, dry environment, away from flammable
materials. Remember to fully charge the unit every three months.
TROUBLESHOOTING
Jumpstart Warning Lights
The iOnBoost is ready to jumpstart when the cables are connected and a steady red light
illuminates on the cable safety block. The following chart displays the combinations of warning
lights that occur when the iOnBoost fails to display the ready light:
Warning lights
Type of warning
Solution
No light
Short-circuit or
incorrect terminal
connection
Disconnect cables and reconnect correctly.
Timer has expired
Reset by pressing manual activation button.
Flashing light
Overload or
overheat
Disconnect cables immediately. Allow unit to
cool for 10 minutes. Plug unit into AC charger
to reset iOnBoost.
Light turns on and
immediately shuts off
after pressing manual
activation button
iOnBoost
undercharged
Charge iOnBoost before proceeding.