10. Start vehicle engine. Stop if the vehicle does not start after 3 to 4 seconds of engine

cranking. Wait 3 to 4 minutes, then try again. If engine does not start after second attempt,

discontinue cranking and consult a professional.

11. When finished, disconnect the clamps in reverse sequence of connecting procedure—

first disconnect negative (black), then positive (red) clamps. Do not let the clamps touch

each other.

12. Disconnect the jumper cable assembly from the unit.
13. When convenient, using either AC or DC charging adapter, completely charge the

iOnBoost battery.

14. Store the unit and charge adapters in a cool, dry environment, away from flammable

materials. Remember to fully charge the unit every three months.

TROUBLESHOOTING

Jumpstart Warning Lights

The iOnBoost is ready to jumpstart when the cables are connected and a steady red light 

illuminates on the cable safety block. The following chart displays the combinations of warning 

lights that occur when the iOnBoost fails to display the ready light:

Warning lights

Type of warning

Solution

No light

Short-circuit or 

incorrect terminal 

connection

Disconnect cables and reconnect correctly.

Timer has expired

Reset by pressing manual activation button.

Flashing light

Overload or 

overheat

Disconnect cables immediately. Allow unit to 

cool for 10 minutes. Plug unit into AC charger 

to reset iOnBoost.

Light turns on and 

immediately shuts off 

after pressing manual 

activation button

iOnBoost 

undercharged

Charge iOnBoost before proceeding.

EN

G

LIS

H

EN

G

LIS

H

Summary of Contents for 7501

Page 1: ...LITHIUM JUMP STARTER POWER BANK Item No 7501 User s Manual BC ...

Page 2: ...S Important Information 4 General Warnings 4 Features 4 Specifications 5 Care Maintenance 5 Charging the iOnBoost 7 Jumpstarter 8 Troubleshooting 10 Using the USB Socket 11 LED Flashlight 11 Proper Disposal 11 ...

Page 3: ...safe operation of any accessory outlet do not place anything in it except the plug of the accessory to be used Use only the charging adapters and jumpstarting clamps provided in this package Unauthorized parts may cause serious damage or injury Wear complete eye and clothing protection when jumpstarting a vehicle Do not touch eyes while working with battery Remove metal personal jewelry such as ri...

Page 4: ...00 A Cranking amps 200 A Jumper cables 10 AWG 8 inch USB power port 5 V 2 1 A Flashlight LED with 3 lighting modes Operating temperatures 32 F 140 F Storage temperatures 32 F 185 F Input 12V 1A Recharging time AC 2 4 hours Recharging time DC with engine running 3 5 hours CARE MAINTENANCE This unit may be stored in any position Make sure the clamps are secure inside the booster cable storage covers...

Page 5: ...inals 7 Carrying case 8 AC charging adapter 9 DC charging adapter 10 Jumper cables 11 Cable safety block 12 Cable indicator light 13 Manual activation button 14 USB charging adapter with mini USB micro USB Apple 30 pin and lightning Actual contents may differ slightly from that pictured 1 6 5 4 2 3 7 8 9 10 14 11 10 12 13 ENGLISH ...

Page 6: ...ights should be steadily illuminated with no flashing Unplug the AC charging adapter from the wall socket first then from the charging jack on the unit 5 The battery status can be checked by tapping on the power button once 6 Store the unit and charge adapters in a cool dry environment away from flammable materials Remember to fully charge the unit every three months DC Charging in Your Vehicle En...

Page 7: ...egative ground systems when jumpstarting Use safety glasses to protect eyes while jumpstarting a battery If the engine fails to start after two 3 second cranking attempts discontinue jumpstart procedure Excessive engine cranking can damage the vehicle s starter motor Look for other problems that may need to be corrected or call for professional service Disconnecting cable clamps is always done in ...

Page 8: ...he iOnBoost s jumper terminal When fully inserted the red and green lights on the cable safety block should both flash continuously Never allow clamps positive negative terminals to touch together or contact the same piece of metal to prevent short circuits and arcing 6 Securely connect the positive red clamp to the positive POS P terminal of the vehicle battery or the remote positive terminal if ...

Page 9: ... flammable materials Remember to fully charge the unit every three months TROUBLESHOOTING Jumpstart Warning Lights The iOnBoost is ready to jumpstart when the cables are connected and a steady red light illuminates on the cable safety block The following chart displays the combinations of warning lights that occur when the iOnBoost fails to display the ready light Warning lights Type of warning So...

Page 10: ... to the iOnBoost Recharge the iOnBoost as soon as convenient LED FLASHLIGHT The light will automatically shut off before the iOnBoost runs out of power 1 Hold down the power button until the indicator lights turn on 3 seconds 2 Press once to switch lighting modes steady flashing SOS morse code off 3 Recharge battery as soon as convenient PROPER DISPOSAL This product has no consumer serviceable par...

Page 11: ...olation of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products There shall be no claims for defects or failure of performance or product failure under any theory of tort contract or commercial law including but not l...

Reviews: