![Waeco SinePower MSP 162 Instruction Manual Download Page 24](http://html1.mh-extra.com/html/waeco/sinepower-msp-162/sinepower-msp-162_instruction-manual_3190000024.webp)
Technical description
SinePower
24
I
Note
Note when connecting devices with an electrical drive (such as
power drills and refrigerators), that they often need more power
than is stated on the type plate.
If the system is overloaded or has a short circuit, the device switches off. If
the input voltage is too high or too low or the system overheats, the device
switches off and then on again after a short while.
The plugs of the MSP 162 and MSP 164 inverters can be inserted in the
socket (fig.
2
1, page 4) for storage.
The inverter has the following connections, displays and control elements:
Pos. in
fig.
1
,
page 3
Element
1
Switches
0 / Off: device is switched off
I / On: device is switched on
II / Remote: device is switched on and off with an external switch
2
Status LED
3
230 V AC safety socket
4
Holders
5
DC connection cable
Pos. in
fig.
2
,
page 4
Element
1
Socket (
MSP 162
and
MSP 164
only) for storing the DC connector.
2
Earth terminal
3
DC connection cable
4
Remote port for connecting to an external switch for switching the device on
and off
5
Fan (
MSP 352
and
MSP 354
only)
_MSP160_MSP350.book Seite 24 Montag, 5. November 2007 4:49 16