Technical data
Article
8100-012VS, 1000-W Inverter
8200-012VS, 2000-W Inverter
Continuous power output:
800 W
1600 W
Continuous power output (30 min.): 1000 W
2000 W
Maximum efficiency:
87%
87%
No-load current:
<0.6 A
<0.8 A
Form of outputvoltage:
Modified sine waves
Modified sine waves
Output frequency:
50±2 Hz
50±2 Hz
Output voltage:
210/240 V
210/240 V
DC input voltage: (1
1
±0
.
3)–(15±0
.
5) V
(1
1
±0
.
3)–(15±0
.
5) V
Low voltage alarm
11±0.3 V
11±0.3 V
Undervoltage disconnection: 10.5±0.3V 10.5±0.3V
Undervoltage reconnection:
12.2±0.6 V
12.2±0.6 V
Overvoltage disconnection: 15.5±0.5V 15.5±0.5V
Excessive temperature disconnection: 60 – 70 °C
60 – 70 °C
Ambient temperature:
–10–40 °C
–10–40 °C
DC fuse:
30 A x 4
30 A x 8
Mains input voltage:
230 V AC
230 V AC
Mains priority circuit:
yes
yes
Weight and dimensions:
4 kg, 210x77x300 mm
6 kg, 210x77x300 mm
Article
8100-012VS, 1000-W Inverter
8200-012VS, 2000-W Inverter
Continuous power output:
800 W
1600 W
Continuous power output (30 min.): 1000 W
2000 W
Maximum efficiency:
87%
87%
No-load current:
<0.4 A
<0.6 A
Form of outputvoltage:
Modified sine waves
Modified sine waves
Output frequency:
50±2 Hz
50±2 Hz
Output voltage:
220/240 V
220/240 V
DC input voltage:
(22±0.6)–(30±1) V
(22±0.6)–(30±1) V
Low voltage alarm
22±0.6 V
22±0.6 V
Undervoltage disconnection:
21±0.6 V
21±0.6 V
Undervoltage reconnection:
24.4±1.2 V
24.4±1.2 V
Overvoltage disconnection:
31±1 V
31±1 V
Excessive temperature disconnection: 60 — 70 °C
60 — 70 °C
Ambient temperature:
–10–40 °C
–10–40 °C
DC fuse:
20 A x 4
20 A x 8
Mains input voltage:
230 V AC
230 V AC
Mains priority circuit:
yes
yes
Weight and dimensions:
4 kg, 210x77x300 mm
6 kg, 210x77x300 mm
Subject to changes due to technical progress and availability.
19
8100-8200 12.09.2003 8:45 Uhr Seite 19