SinePower
Safety instructions
37
Electrical cables
z
If cables have to be fed through metal walls or other walls with sharp edg-
es, use ducts or wire bushings to prevent damage.
z
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
z
Do not pull on the cables.
z
Do not lay the 230 V mains cable and the 12/24 V DC cable in the same
duct.
z
Fasten the cables securely.
z
Lay the cables so that they cannot be tripped over or damaged.
2.3
Operating the appliance safely
z
Operate the device only if you are certain that the housing and the cables
are undamaged.
z
Make sure the air inlets and outlets of the device are not covered.
z
Ensure good ventilation.
z
Do
not
connect the 230 V output of the inverter (fig.
2
4, page 4) to a
different 230 V source.
z
Even after the fuse triggers, parts of the inverter remain live.
z
Always disconnect the power supply when working on the device.