Disposal
ColdMachine
50
10
Disposal
➤
Place the packaging material in the appropriate recycling waste bins
wherever possible.
When it comes time to scrap the device, ask your local recycling
centre or dealer for details about how to do this in accordance with
the applicable disposal regulations.
11
Troubleshooting
LED on the thermal element (fig.
1
2, page 3)
Number of
flashes
Error type
Remedy
1
Battery protection shutdown
Check battery voltage, fuse and
cable cross section
2
Fan overvoltage shutdown
Check condenser and vaporiser fan
current:
total target value < 0.5 A
3
Compressor start-up fault
Reduce load on cooling system:
– Ensure good ventilation around the
cooling unit
– Store pre-cooled goods
4
Compressor overload shutdown
Reduce load on cooling system:
– Ensure good ventilation around the
cooling unit
– Store pre-cooled goods
5
Electronic fuse shutdown
Reduce load on cooling system:
– Ensure good ventilation around the
cooling unit
_coldmachine.book Seite 50 Mittwoch, 30. April 2008 3:26 15