EN
Initial start-up
ASC5500G RPA
92
7.12.2
Refrigerant analysis failed
If the refrigerant fails the analysis, the AirConServiceCenter displays the
following:
1. Confirm
“Try again”
with
ENTER
.
The AirConServiceCenter checks up to three times. If the third analysis
is still not successful, the AirConServiceCenter displays the following:
2. Press
STOP
.
3. Connect the waste container to the waste terminal and press
ENTER
to confirm.
4. Once the AirConServiceCenter has disposed of the sample, dis-
connect the AirConServiceCenter from the vehicle and drain the
service hoses.
5. Switch off the unit and take unit outside.
!
6. Loosen the high and low pressure service connection carefully and
release the gas.
7. Verify the analysis unit of the AirConServiceCenter: see chapter
“Verifying the analysis unit” on page 93.
Refrigerant Test
Fail
Try again?
ENTER-OK
No
WARNING !
Bad refrigerant!
Read user manual!
PLS contact the car
manufacturer!
ENTER-OK
CAUTION!
Wear protective gloves and goggles.
Summary of Contents for ASC5500G RPA