EN
91
AirConServiceCenter
Service tasks
8.4
Calibrating the pressure transducer
The pressure transducer has to be correctly calibrated in order to make
accurate pressure measurements.
Calibration is required:
every four weeks,
if the AirConServiceCenter has been subjected to heavy shaking,
every time the vacuum pump oil is changed,
if the display shows implausible pressure readings.
1. In standby mode, use the cursor keys
or
to select
“Other selections
”:
2. Press
ENTER
to confirm.
3. Use the cursor keys
or
to select
“Service
”:
4. Press
ENTER
to confirm.
5. Enter the password
“2224
”.
6. Select
“Pressure transducer
” with
ENTER
.
7. Then follow the instructions in the display.
– Unscrew the service couplings (
13
) and (
14
) from the service
hoses (
11
) and (
12
).
– Use the keypad (
7
) to enter the current local atmospheric
pressure and press
ENTER
to confirm.
I
8. When calibration has been completed, press
ENTER
to quit the
menu.
9. Press
STOP
twice to go to standby mode.
10. Screw the service couplings (
13
) and (
14
) hand-tight onto the service
hoses (
11
) and (
12
), taking care not to mix up the red and blue mark-
ings on the couplings and hoses.
Short selection
Free selection
Other selections
ENTER-OK
Int.vessel filling
Flushing
Reset Scales.
Service.
NOTE
You can look up the current atmospheric pressure for your region on the
internet, for example at http://www.meteo24.de/wetter/ under “Luft-
druck”.
Summary of Contents for AirConServiceCenter ASC1000
Page 2: ......
Page 218: ...RU AirConServiceCenter 218 2 3 405 C R 134a...
Page 219: ...RU 219 AirConServiceCenter 2 4 TRG 402 AirConServiceCenter...
Page 220: ...RU AirConServiceCenter 220 2 5 AirConServiceCenter 230 50 2 6...
Page 233: ...RU 233 AirConServiceCenter 6 10 ASC2000RPA I 1 12 2 8 3 12 AirConServiceCenter 8...
Page 238: ...RU AirConServiceCenter 238 I 7 2 2 1 STOP Enter user code Wrong code Max Mustermann...
Page 251: ...RU 251 AirConServiceCenter 8 Process start ENTER 9 D 10 E 11 15 D D E...
Page 259: ...RU 259 AirConServiceCenter 9 9 1 A 9 2 9 3 AirConServiceCenter WAECO...
Page 263: ...RU 263 AirConServiceCenter Error 11 Error 12 10 C Error 60 Error 61...
Page 267: ...RU 267 AirConServiceCenter...