11. Disconnect the system components which cannot be flushed from
the refrigerant circuit. These components include:
– Compressor
– Line filter
– Fixed choke
– Collection containers
– Filter drying units
– Expansion valve
12. Connect the components for flushing to the service ports (
12
)
and (
13
) of the AirConServiceCenter using special adapters and in
accordance with the manufacturer's specifications to form a flushing
circuit.
I
13. In the basic menu, use the cursor keys
or
to select
“Other selections”
:
14. Press
ENTER
to confirm.
15. Use the cursor keys
or
to select
“Flushing”
:
16. If necessary, use the keypad (
7
) to enter the data and press
ENTER
to confirm.
If no data is to be entered, press
ENTER
to switch to the next
program step.
17. Use the cursor keys
or
to select whether to flush the entire air
conditioning system or just individual components:
18. Press
ENTER
to confirm.
19. Follow the instructions in the display.
✓
After flushing is completed, the basic menu for the
AirConServiceCenter appears.
NOTE
Observe the guidelines on repairs from the vehicle manufacturer.
Short selection
Free selection
Other selections
ENTER-OK
Flushing
Reset scales.
Service.
ENTER-OK STOP-EXIT
Full flushing
Fast flushing
ENTER-OK STOP-EXIT