ASC 5300 G
Service tasks
“Service completed”
displays the amount of service work performed
using the air conditioning service unit since the last reset (see date).
9.5
Calibrating the pressure transducer
I
1. In the basic menu, use the cursor keys
or
to select
“Other
selections”
:
2. Depressurise the unit (as described in chapter “Changing the dryer
3. Press
ENTER
to confirm.
4. Use the cursor keys
or
to select
“Service”
:
5. Press
ENTER
to confirm.
6. Enter the password
“2224”
.
7. Confirm
“Pressure transducer”
by pressing
ENTER
.
8. Then follow the instructions in the display.
– Unscrew the service couplings (
12
) and (
13
) from the service
hoses (
10
) and (
11
).
– Use the keypad (
7
) to enter the current local atmospheric pressure
and press
ENTER
to confirm.
Service completed:
08/03/15
Number
4
STOP-EXIT
NOTE
The pressure transducer has to be correctly calibrated in order to make
accurate pressure measurements.
Calibration is required:
Every four weeks
If the AirConServiceCenter has been subjected to heavy shaking
Every time the vacuum pump oil is changed
If the display shows implausible pressure readings
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.