EN
RefrigerantScale
Operation
13
6.3
Charging refrigerant
I
1. Connect the device to the AC mains using the AC cable
, page 3).
2. Connect a filled refrigerant bottle to the “Input” connection
, page 3).
3. Connect the gas bottle to be filled to the “Output” connection
, page 3).
4. Switch on the device using the on/off switch (fig.
3
5. Place the filled gas bottle on the scale (fig.
, page 5).
6. Wait until the scale has determined the current weight and shown this in
the display.
7. Press the “Charge” button (fig.
1
8. Enter the intended charging weight (min. 50 g) using the numerical keys.
9. Press the “Enter” button (fig.
, page 4).
✔
The solenoid valve is opened and the refrigerant is charged.
The solenoid valve closes when the selected refrigerant quantity has
been charged.
The device displays the quantity of refrigerant remaining in the filled
refrigerant gas bottle.
I
6.4
Recovering refrigerant
I
NOTE
The refrigerant scale must be connected to the AC mains in order
for the solenoid valve to work.
NOTE
Press the “Enter” button (fig.
6
, page 4) to stop a process
at any time. After this press the “Charge” button
(fig.
, page 4) to return to the previous screen.
If you want to end the charging process before the selected
quantity of refrigerant has been reached, press the “0” button.
Press the “Enter” button (fig.
6
, page 4) to exit the mode.
NOTE
If the weight selected exceeds the total weight of refrigerant in
the gas bottle, the fault message “ERROR” is displayed.
The weight of the bottle to be filled must not exceed 80 % of
the total quantity.
Summary of Contents for 8885100099
Page 3: ...RefrigerantScale 3 1 2 3 4 1 1 2 3 2...
Page 4: ...RefrigerantScale 4 6 1 2 3 5 4 3 1 2 3 4 5 6 8 7 4...
Page 5: ...RefrigerantScale 5 5 6...
Page 126: ...RU RefrigerantScale 126 A I 2 2 1 8...
Page 127: ...RU RefrigerantScale 127 8 A 2 2 A 30...
Page 128: ...RU RefrigerantScale 128 3 4 30 8885100099 Dometic 1 3 1 2 3 4...
Page 129: ...RU RefrigerantScale 129 5 30 Input Output 5 1 2 3 1 Input 30 2 Output 3 3 4 1 2 3 4 5 6...
Page 131: ...RU RefrigerantScale 131 6 A I 6 1 oz lb Function 4 2 4 6 2 30 Light 4 3 4 30 Input Output...
Page 134: ...RU RefrigerantScale 134 6 5 Repeat 3 5 4 7 1 2 9 3 8 9 A ERROR Power 3 Power...
Page 135: ...RU RefrigerantScale 135 10 dometic com dealer 11...
Page 178: ......
Page 179: ......