Operation
PT 3 / PT 3A / PT 3H
24
wc_tx001779gb.fm
4.4
Before Starting
See Graphic: wc_gr000013
4.4.1
Read safety instructions at the beginning of this Operator’s Manual.
4.4.2
Place pump as near to water as possible, on a firm, flat, level surface.
4.4.3
To prime pump, remove prime plug
(a)
and fill pump housing with
water. If the pump housing is not filled with water before starting, it will
not begin pumping.
Do not open priming plug, discharge plug, or loosen hose fittings if
pump is hot! Water or vapor inside pump may be under pressure.
4.4.4
Check for leaks between pump and engine. If water is leaking, the seal
inside pump is worn or damaged. Continued operation may cause
water damage to engine.
4.4.5
Check that hoses are securely attached to pump. Suction hose
(b)
must not have any air leaks. Tighten hose clamps
(c)
and couplings
(d)
. Check that discharge hose
(e)
is not restricted. Lay hose out as
straight as possible. Remove any twists or sharp bends from hose
which may block the flow of water.
4.4.6
Make sure suction strainer
(f)
is clean and securely attached to end of
hose. The strainer is designed to protect the pump by preventing large
objects from being pulled into the pump.
NOTICE
: Strainer should be positioned so it will remain completely
under water. Running the pump with the strainer above water for long
periods can damage the pump.
4.4.7
Check fuel level, engine oil level, and condition of air cleaner.
WARNING
Summary of Contents for PT 3H
Page 1: ...5000185222 11 0711 5 0 0 0 1 8 5 2 2 2 Operator s Manual Pump PT 3 PT 3A PT 3H EN...
Page 6: ......
Page 25: ...PT 3 PT 3A PT 3H Operation wc_tx001779gb fm 25...
Page 43: ...PT 3 PT 3A PT 3H Maintenance wc_tx001776gb fm 43 d a b c e h g g f h wc_gr008242...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......