![Wacker Neuson PT 3H Operator'S Manual Download Page 48](http://html1.mh-extra.com/html/wacker-neuson/pt-3h/pt-3h_operators-manual_3128549048.webp)
Maintenance
PT 3 / PT 3A / PT 3H
48
wc_tx001776gb.fm
5.17
Basic Troubleshooting
Problem / Symptom
Reason / Remedy
Pump does not take in water.
• Not enough priming water in housing.
• Engine speed too low. Adjust speed.
• Strainer plugged. Clean strainer.
• Suction hose damaged. Replace or repair hose.
• Air leak at suction port. Check that fittings are tight
and housing cover O-rings are sealing properly.
• Pump too high above water.
• Debris collecting in pump housing. Clean pump
housing.
• Too much clearance between impeller and insert.
Pump takes in water, little or
no discharge.
• Engine speed too low. Adjust speed.
• Suction strainer partially plugged. Clean strainer.
• Impeller worn. Adjust clearance by adding shims or
replace impeller.
• Volute insert worn or damaged. Adjust clearance or
replace insert.
Suction hose leaks at inlet.
• Clamps are not sealing properly. Tighten, replace, or
add clamp.
• Hose diameter is too large.
• Hose is damaged.
Discharge hose does not stay
on coupling.
• Pressure may be too high for clamps being used.
Add another clamp.
• Hose kinked or end blocked. Check hose.
Impeller does not turn; pump
is hard to start.
• Impeller jammed or blocked. Open pump cover and
clean dirt and debris from inside of pump housing.
• Impeller and insert binding. Adjust clearance by
removing shim from behind insert.
Summary of Contents for PT 3H
Page 1: ...5000185222 11 0711 5 0 0 0 1 8 5 2 2 2 Operator s Manual Pump PT 3 PT 3A PT 3H EN...
Page 6: ......
Page 25: ...PT 3 PT 3A PT 3H Operation wc_tx001779gb fm 25...
Page 43: ...PT 3 PT 3A PT 3H Maintenance wc_tx001776gb fm 43 d a b c e h g g f h wc_gr008242...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......