Air Cleaner (Wacker Neuson)
See Graphic: wc_gr000656
NEVER use gasoline or other types of low-flash point solvents for
cleaning the air cleaner. A fire or explosion could result.
NOTICE:
NEVER run the engine without the air cleaner. Severe
engine damage will occur.
The engine is equipped with a dual-element air cleaner. Under normal
operating conditions, the elements should be cleaned once every
week. Under severe, dry and dusty conditions, the elements should be
maintained daily. Replace an element when it is saturated with dirt that
cannot be removed.
5.5.1
Remove the air cleaner cover
(a)
. Remove the filter assembly by
pulling it straight up. Inspect both elements for holes or tears. Replace
damaged elements.
5.5.2
Wash the foam element
(b)
in a solution of mild detergent and warm
water. Rinse it thoroughly in clean water. Allow the element to dry
thoroughly.
5.5.3
Tap the paper element
(c)
lightly to remove excess dirt or blow
compressed air through the filter from the inside out. Replace the
paper element if it appears heavily soiled.
WARNING
c
b
a
wc_gr000656
Summary of Contents for PT 3H
Page 1: ...5000185222 11 0711 5 0 0 0 1 8 5 2 2 2 Operator s Manual Pump PT 3 PT 3A PT 3H EN...
Page 6: ......
Page 25: ...PT 3 PT 3A PT 3H Operation wc_tx001779gb fm 25...
Page 43: ...PT 3 PT 3A PT 3H Maintenance wc_tx001776gb fm 43 d a b c e h g g f h wc_gr008242...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......