Lubricant capacity: Specified capacity (Refer to the table, “Specified
Lubricant Capacity”.)
Inspecting Lubricant
Remove the oil plug and take out a small amount of oil. The oil can be
extracted easily by tilting the pump so that the oil plug faces downward.
If the oil appears discolored or intermixed with water, a likely cause is
a defective shaft-sealing device (i.e. mechanical seal), which requires
that the pump be disassembled and repaired.
See Graphic: wc_gr000336
Changing Lubricant
Remove the oil plug and drain the oil completely. Pour a specified
volume of oil into the oil filler inlet.
Note:
The drained oil must be disposed of by waste disposal
contractors in compliance with the laws of the locale where the pump
is being used.
Note:
The gasket and the O-ring for the oil plug must be replaced with
a new part at each oil inspection and change.
Ref.
Description
Ref.
Description
1.
Oil Inlet
3.
Oil Plug
2.
Gasket
4.
Allen Wrench
Model
Specified Lubricant Capacity
PS2 1503
PS2 2203
PS3 1503
PS3 2203
740 ml (25.0 fl.oz.)
PS2 3703
PS4 3703
PS3 3703
960 ml (32.5 fl.oz.)
PS4 5503
PS3 5503
1100 ml (37.2 fl.oz.)
wc gr000336
Summary of Contents for PS 2 1503
Page 1: ...Pump PS 3 Phase Series OPERATOR S MANUAL 0154626en 002 0409 0 1 5 4 6 2 6 E N ...
Page 2: ......
Page 4: ...Table of Contents PS 3 Phase Series wc_bo0154626002enTOC fm 2 ...
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......