LTN 6L
Maintenance
wc_tx000767gb.fm
55
6.3.2
Remove the lens
(c)
with the gasket
(d)
attached.
6.3.3
Remove the hardware securing one side of the lamp stabilizer
(e)
.
Once removed, swing the lamp stabilizer to the side and unscrew the
lamp
(f)
.
Installing the lamp
6.3.4
Screw the lamp in firmly, but not forcibly, to minimize loosening due to
vibration. Secure it with the lamp stabilizer.
6.3.5
Install the gasket around the lens and secure the lens to the reflector
with the flange rings and screws.
6.4
Daily Inspection
6.4.1
Check for fluid leaks. Check fluid levels.
6.4.2
Inspect condition of electrical cords. Do not use Light Tower if
insulation is cut or worn through.
6.4.3
Check that winch cables are in good condition. Do not use a cable that
is kinked or starting to unravel.
6.4.4
Check that the vertical tower locking pin and its spring are secured,
aligned, and operating properly.