HI 400HD D / HD G
Operation
ghi_tx001462gb.fm
41
4.23
Stopping
Procedure
Follow the procedure below to stop the machine.
1. Turn the operation mode switch to the OFF (0) position
(c)
.
Shutdown
sequence
The following sequence of events will occur after turning the machine off.
1. The burner will shut down.
2. The blower will stop when the machine is sufficiently cool.
4.24
Burner Fault
The burner fault lamp / reset button
(a)
is illuminated while the machine is
operating. The lamp is green during normal operation.
Burner fault
A burner fault occurs if the burner does not fire upon startup. The lamp will turn red.
The lamp will also turn red if the burner goes out while the machine is operating.
To clear a burner fault, press and hold the burner fault lamp / reset button for
2–3 seconds until the lamp goes out.
Re-start the machine.
If the burner fault re-occurs, see
Basic Troubleshooting.
WARNING
Electric shock hazard. Electric power is still active at the blower even when the
machine is turned OFF.
f
Remove all electric power to the machine before servicing the machine.
c
0
RESET
wc_gr007620
a
Summary of Contents for HI 400 HD D
Page 67: ......