Operation
HI 400HD D / HD G
20
ghi_tx001462gb.fm
4.3
Installing the Front Duct Adapter
Overview
The front duct adapter provided with your machine is shipped loose and must be
installed before operating the machine. The thermostat probe must also be
installed on the inside of the duct adapter during this procedure.
Procedure
Follow the procedure below to install the front duct adapter and thermostat probe.
1. The thermostat probe
(a)
is temporarily mounted on a disposable bracket
(b)
inside the machine shell. Remove and set aside the mounting screw
(c
) to
disconnect the bracket from the machine shell.
2. Remove the screw fastening the thermostat probe to the disposable bracket,
and discard the bracket. Temporarily rest the thermostat probe inside the
machine shell.
Note:
Do not discard the screw. It will be used to mount the thermostat probe.
3. Slide the edge of the duct adapter
(d)
beneath the edges of the upper and lower
machine shell.
4. Align the four threaded mounting holes
(e)
on the duct adapter with the
corresponding holes on the machine shell.
5. Use the screws (provided) to fasten the duct adapter to the machine shell.
6. Align the thermostat probe inside the duct adapter as shown. Fasten the
thermostat probe in place using the reserved bracket screw.
wc_gr007766
a
a
b
c
d
e
Summary of Contents for HI 400 HD D