BA 5001-6001 US – Edition 1.2 * 6001b510.fm
5-5
Maintenance
5.3
Fuel system
Specific safety instructions
WARNING
Fire and fume inhalation hazards.
☞
Do not refuel in closed rooms.
☞
Never perform maintenance or repair work on the fuel system in the vicinity
of open flames or sparks.
☞
Never smoke when working on the fuel system or when refueling.
☞
Before refueling, stop the engine and remove the starter key.
☞
Wipe up any fuel spills immediately.
☞
Remove spilled fuel from the machine components and surfaces before use
to reduce the risk of fire.
Refueling
Filler inlet
A
for the fuel tank is located behind the right-hand side servicing lid.
Environment
Use a suitable container to collect the fuel as it drains and dispose of it in an
environmentally friendly manner!
Important
Do not run the fuel tank completely dry. Otherwise, air is drawn into the fuel
system. This requires bleeding the fuel system
– see
Bleeding the fuel system
on page 5-7.
Important
Fill up the tank with the correct fuel type at the end of each working day. This
prevents condensation water from forming in the fuel tank over night. Do not fill
the tank completely but leave some space for the fuel to expand.
Fig. 73: Refueling: 6001/9001/10001 with cab
Fig. 73: Refueling (6001)
A
A
Summary of Contents for Dumper 5001
Page 8: ...I 6 BA 5001 6001 US Edition 1 2 Ba6001us1_1SIX fm Index...
Page 15: ...BA 5001 6001 US Edition 1 2 6001b110 fm 1 7 Introduction 1 7 Swivel dump bucket 5001 6001...
Page 16: ...1 8 BA 5001 6001 US Edition 1 2 6001b110 fm Introduction 1 8 Front dump bucket 6001...
Page 32: ...2 12 BA 5001 6001 US Edition 1 2 6001b210 fm Safety Information...
Page 118: ...5 40 BA 5001 6001 DE Edition 1 2 6001b560 fm Maintenance...