3-10
OM 803 us – Edition 3.7 * * 803b320.fm
Operation
3.5 Machine travel
Starter
Throttle
Speed is set continuously with throttle
➥
Position
A
: idling speed
➥
Position
B
: max. engine speed
1
0
2
3
Fig. 49: Preheating start switch
Position Function
Power consumer
0
Insert or remove the starting key
None
1
ON/travel position
Feed pump switched on
➥
Indicator lights illuminate
2
Preheats the engine (10 – 15 seconds)
Glow plugs
3
Starts the engine
Starter
Fig. 50: Engine speed control (up to serial no. AI00814)
B
A
Fig. 51: Engine speed control (from serial no. AI00815)
B
A