3-69
Operation
Changeover from diesel to HPU operation
Key
A
for changing over between HPU and diesel operation is located in the document
box behind the operator seat.
1
Stop the diesel engine: turn the starting key to position
0
.
2
Insert key
A
and turn it clockwise to position
2
.
3
Remove key
A
and store it in the document box.
➥
Indication
B
must be in position
2
.
Switch on the HPU: press the green push button
(G)
Fig. 153:
Fig. 154:
1
0
2
3
Fig. 155:
A
Fig. 156:
2
B
Fig. 157:
7.5 kW version
9 kW version
G